ArticleslgStudy

engineering

Fully differential amplifier

Fully differential amplifier is a engineering topic covered in the lgStudy science library. This page brings together a partial reference excerpt, illustrations, worked examples, real-world applications and a short study plan, so you can understand Fully differential amplifier rather than just read about it. In short: A fully differential amplifier (FDA) is a DC-coupled high-gain electronic voltage amplifier with differential inputs and outputs. In its ordinary usage, the output of the FDA is controlled by two feedback paths which, because of the amplifier's high gain, almost completely determine the output voltage for any given input.

Key takeaways

  • Fully differential amplifier belongs to engineering; place it in that map before memorising details.
  • Learn the definition first, then one example that makes the definition concrete.
  • Connect Fully differential amplifier to a quantity you can measure, compute or draw — that is where exam questions come from.
  • Reproduce the core statement of Fully differential amplifier from memory before moving on to harder problems.

Reference excerpt

A fully differential amplifier (FDA) is a DC-coupled high-gain electronic voltage amplifier with differential inputs and outputs. In its ordinary usage, the output of the FDA is controlled by two feedback paths which, because of the amplifier's high gain, almost completely determine the output voltage for any given input. In a fully differential amplifier, common-mode noise such as power supply disturbances is rejected; this makes FDAs especially useful as part of a mixed-signal integrated circuit. An FDA is often used to convert an analog signal into a form more suitable for driving into an analog-to-digital converter; many modern high-precision ADCs have differential inputs.

The ideal FDA For any input voltages, the ideal FDA has infinite open-loop gain, infinite bandwidth, infinite input impedance resulting in zero input currents, infinite slew rate, zero output impedance and zero noise. In the ideal FDA, the difference in the output voltages is equal to the difference between the input voltages multiplied by the gain. The common mode voltage of the output voltages is not dependent on the input voltage. In many cases, the common mode voltage can be directly set by a third voltage input.

Input voltage: V i d = V i n + − V i n − {\displaystyle V_{\mathrm {id} }=V_{\mathrm {in+} }-V_{\mathrm {in-} }}

Output voltage: V o d = V o u t + − V o u t − = V i d × G a i n {\displaystyle V_{\mathrm {od} }=V_{\mathrm {out+} }-V_{\mathrm {out-} }=V_{\mathrm {id} }\times \mathrm {Gain} }

Output common-mode voltage: V o c = ( V o u t + ) + ( V o u t − ) 2 {\displaystyle V_{\mathrm {oc} }={\frac {(V_{\mathrm {out+} })+(V_{\mathrm {out-} })}{2}}}

A real FDA can only approximate this ideal, and the actual parameters are subject to drift over time and with changes in temperature, input conditions, etc. Modern integrated FET or MOSFET FDAs approximate more closely to these ideals than bipolar ICs where large signals must be handled at room temperature over a limited bandwidth; input impedance, in particular, is much higher, although the bipolar FDA usually exhibit superior (i.e., lower) input offset drift and noise characteristics. Where the limitations of real devices can be ignored, an FDA can be viewed as a Black Box with gain; circuit function and parameters are determined by feedback, usually negative. An FDA, as implemented in practice, is moderately complex integrated circuit.

Limitations of real FDAs

DC imperfections Finite gain — the effect is most pronounced when the overall design attempts to achieve gain close to the inherent gain of the FDA. Finite input resistance — this puts an upper bound on the resistances in the feedback circuit. Nonzero output resistance — important for low resistance loads. Except for very small voltage output, power considerations usually come into play first. (Output impedance is inversely proportional to the idle current in the output stage — very low idle current results in very high output impedance.) Input bias current — a small amount of current (typically ~10 nA for bipolar FDAs, or picoamperes for CMOS designs) flows into the inputs. This current is mismatched slightly between the inverting and non-inverting inputs (there is an input offset current). This effect is usually important only for very low-power circuits. Input offset voltage — the FDA will produce an output even when the input pins are at exactly the same voltage. For circuits that require precise DC operation, this effect must be compensated for. Common mode gain — A perfect operational amplifier amplifies only the voltage difference between its two inputs, completely rejecting all voltages that are common to both. However, the differential input stage of an FDA is never perfect, leading to the amplification of these identical voltages to some degree. The standard measure of this defect is called the common-mode rejection ratio (denoted, CMRR). Minimization of common mode gain is usually important in non-inverting amplifiers (described below) that operate at high amplification. Temperature effects — all parameters change with temperature. The temperature drift of the input offset voltage is especially important.

AC imperfections Finite bandwidth — all amplifiers have a finite bandwidth. This is because FDAs use internal frequency compensation to increase the phase margin. Input capacitance — most important for high-frequency operation because it further reduces the open loop bandwidth of the amplifier. Common mode gain — See DC imperfections, above. Noise - all real electronic components generate noise.

… excerpt ends here. Continue reading the full article.

Worked examples

Example 1 — a first encounter with Fully differential amplifier

Start with the simplest possible case. Write down what Fully differential amplifier claims or describes in one sentence, then invent the smallest concrete situation in which that sentence is true. In engineering, the smallest case is usually a single object, a single equation or a single measurement. Check that every symbol or term in your sentence has a meaning in that case.

Example 2 — changing one variable

Take the situation from Example 1 and change exactly one quantity: double it, halve it, or set it to zero. Predict what should happen to Fully differential amplifier before you calculate. Comparing your prediction with the result is the fastest way to find out whether you understand the idea or only the words.

Example 3 — an exam-style question

Typical questions about Fully differential amplifier ask you to (a) state it precisely, (b) apply it to given data, and (c) explain a limitation. Practise writing all three answers in under five minutes; the third part is what separates a full-mark answer from an average one.

Applications of Fully differential amplifier

In research
Fully differential amplifier appears in engineering research whenever the underlying quantities have to be modelled precisely. Papers usually cite it as a starting assumption and then explore where it breaks down.
In technology and industry
Engineering practice reuses Fully differential amplifier in design rules, simulations and safety margins. Knowing the idea lets you read a specification sheet and understand why the numbers look the way they do.
In the classroom
Fully differential amplifier is common in secondary-school and first-year university syllabi. It links to neighbouring topics Electronic amplifiers, Integrated circuits, so understanding it makes those chapters shorter.
In everyday life
Look for Fully differential amplifier outside the textbook — in sport, cooking, traffic, electronics or the sky above you. An example you found yourself is remembered far longer than one you were given.
Ask Teacher Smith questions about this articleOpens your AI tutor with a question about “Fully differential amplifier” →

Affiliate

Preply — study more efficiently by working with a personal tutor. 50% off.

How to study Fully differential amplifier in 20 minutes

  1. Read the reference excerpt below once, without taking notes.
  2. Close the page and write down what Fully differential amplifier means in your own words.
  3. Compare your version with the excerpt and mark what you missed.
  4. Work through the three examples above with pen and paper.
  5. Explain Fully differential amplifier out loud to somebody else — or to Teacher Smith in the lgStudy chat.

Frequently asked questions

What is Fully differential amplifier in simple terms?

A fully differential amplifier (FDA) is a DC-coupled high-gain electronic voltage amplifier with differential inputs and outputs. In its ordinary usage, the output of the FDA is controlled by two feedback paths which, because of the amplifier's high gain, almost completely determine the output volt…

Why does Fully differential amplifier matter?

Because it connects several engineering ideas at once: it gives you a definition you can apply, a quantity you can calculate, and a way to check whether a result is plausible.

How should I study Fully differential amplifier?

Read the excerpt, restate it from memory, then work through the examples and applications listed on this page. The five-step study plan above takes about twenty minutes.

What does this page cover?

It gives you a compact reference excerpt plus original lgStudy explanations, examples, applications and study material on Fully differential amplifier.

Tags

  • Electronic amplifiers
  • Integrated circuits

Keep exploring