ArticleslgStudy

science

High efficiency glandless circulating pump

High efficiency glandless circulating pump is a science topic covered in the lgStudy science library. This page brings together a partial reference excerpt, illustrations, worked examples, real-world applications and a short study plan, so you can understand High efficiency glandless circulating pump rather than just read about it. In short: A high efficiency glandless circulating pump is a component of a heating and air conditioning system that allows the system to perform with increased efficiency while significantly reducing the system's electrical usage. Description The pump is primarily composed of an electronically commutated synchronous motor (ECM) with a permanent magnet rotor.

High efficiency glandless circulating pump — main illustration
High efficiency glandless circulating pump — illustration

Key takeaways

  • High efficiency glandless circulating pump belongs to science; place it in that map before memorising details.
  • Learn the definition first, then one example that makes the definition concrete.
  • Connect High efficiency glandless circulating pump to a quantity you can measure, compute or draw — that is where exam questions come from.
  • Reproduce the core statement of High efficiency glandless circulating pump from memory before moving on to harder problems.

Reference excerpt

A high efficiency glandless circulating pump is a component of a heating and air conditioning system that allows the system to perform with increased efficiency while significantly reducing the system's electrical usage.

Description The pump is primarily composed of an electronically commutated synchronous motor (ECM) with a permanent magnet rotor. The ECM is a motor that converts a direct current (DC) from an electrical source into an alternating current (AC) which is sent to the motor itself, allowing for increased efficiency over standard AC motors. The permanent magnet rotor consists of an iron core, surrounded by multiple magnetic rare earth metals, and finally a metal sleeve that evenly spaces the magnets around the core, which helps to drive the motor. By utilizing multiple small improvements in pump-design technology such as a double pump in parallel system and variable controls, these pumps are able to run at about a 50% to 70% increased efficiency with up to an 80% decrease in electricity consumption over the previous standard design. This pump has recently become the new standard in both commercial and residential buildings across the European Union due to a recent ordinance by the European ErP (Eco-Design) Directive. The ErP directive began enforcing this new standard of regulation of these pumps 1 January 2013 and will become even stricter on efficiency standards on 1 August 2015 in order to meet the EU's goal of a 50% total reduction in the pump's energy usage by 2020.

Pump design

Primary factors

The primary design factors of a high efficiency glandless circulating pump include an electronically commutated synchronous motor, a permanent magnet rotor, and canned rotor technology. An electronically commutated synchronous motor is used to convert the energy current from a DC energy source into an AC current which is supplied to the drive motor. It utilizes the magnetomotive force which is generated by surface currents placed on the surfaces of the stator and rotor and the permanent magnets to generate the electric current which is in output to the drive motor. The canned rotor technology eliminates the need for a shaft seal that many conventional pumps must use through its unique design. Whereas standard pumps with shaft seals have multiple chambers with different rotating parts in each, canned rotor technology allows all of the rotating parts within the pump to exist in a single chamber. This increases the overall efficiency since the liquid used to lubricate the shaft bearings is also used to cool the motor. The electronic components of the motor are attached outside this system by means of an encapsulated motor cartridge, which is an independent metal compartment used solely for housing the electronic components.

Secondary factors Many minor factors of the pump's design including its double pump system and control options give it additional efficiency without sacrificing any of its performance. By using a double pump system together with variable and automatic control, the pump is able to decrease its energy consumption while increasing efficiency and reliability. Using the pump's variable controls allows the pump to base its amount of energy consumption on how much it is actually performing, cutting down on usage during non-peak hours and extending the pump's life span. The automatic controls allow the pump to follow a set schedule of how much energy to consume during specific hours, which allows building owners to cut down even further on electricity costs. By dividing the output into a double pump in parallel design, the system is able to greatly adapt to partial load conditions. This accounts for a significant increase in reliability and the 50% to 70% efficiency increase that these high efficiency pumps achieve.

Implementation These types of pumps are used primarily in heating and air conditioning systems within both residential and commercial buildings such as offices and apartment complexes. The pump is the central component of these systems and accounts for most of the electricity usage within the system, making its design key to an increase in efficiency and decrease in energy consumption. Although the pump can be installed both inside and outside of buildings, many precautions must be taken in order to protect the pump from unfavorable weather conditions. These pumps are fairly simple to integrate into systems that follow the old standard since each pump is able to increase its efficiency by changing its design internally, meaning it will still fit into older systems without any problems requiring special adapters.

Necessity High efficiency glandless circulating pumps have become the industry standard when developing and maintaining buildings within the European Union due to recent changes to the carbon emissions goals. Commercial and residential buildings now have to be outfitted with these pumps in order to decrease electricity usage and, in the long run, decrease the amount of pollutants produced. This new standard, referred to as the energy efficiency index (EEI), will set the bare minimum efficiency level at 0.27, and set the efficiency grading scale from this base value. The EU has also scheduled the efficiency scale to be revised again by 1 August 2015 to set the minimum efficiency to 0.23. Various companies such as Wilo have successfully developed pumps that have been projected to save up to 80% in electricity usage, meeting both of the new grading scale minimums set this year and in 2015. Pump designs are still being revised to continually try to achieve higher efficiency standards and lower the impact on the environment in order to meet the goal of up to a 50% reduction in both CO2 emissions and electricity usage across the EU by 2020.

References

Illustrations

High efficiency glandless circulating pump: Three different high efficiency glandless circulating pumps designed and developed by the company Wilo.
Three different high efficiency glandless circulating pumps designed and developed by the company Wilo.
High efficiency glandless circulating pump: Diagram of the different components that make up a standard high efficiency glandless circulating pump.
Diagram of the different components that make up a standard high efficiency glandless circulating pump.

Worked examples

Example 1 — a first encounter with High efficiency glandless circulating pump

Start with the simplest possible case. Write down what High efficiency glandless circulating pump claims or describes in one sentence, then invent the smallest concrete situation in which that sentence is true. In science, the smallest case is usually a single object, a single equation or a single measurement. Check that every symbol or term in your sentence has a meaning in that case.

Example 2 — changing one variable

Take the situation from Example 1 and change exactly one quantity: double it, halve it, or set it to zero. Predict what should happen to High efficiency glandless circulating pump before you calculate. Comparing your prediction with the result is the fastest way to find out whether you understand the idea or only the words.

Example 3 — an exam-style question

Typical questions about High efficiency glandless circulating pump ask you to (a) state it precisely, (b) apply it to given data, and (c) explain a limitation. Practise writing all three answers in under five minutes; the third part is what separates a full-mark answer from an average one.

Applications of High efficiency glandless circulating pump

In research
High efficiency glandless circulating pump appears in science research whenever the underlying quantities have to be modelled precisely. Papers usually cite it as a starting assumption and then explore where it breaks down.
In technology and industry
Engineering practice reuses High efficiency glandless circulating pump in design rules, simulations and safety margins. Knowing the idea lets you read a specification sheet and understand why the numbers look the way they do.
In the classroom
High efficiency glandless circulating pump is common in secondary-school and first-year university syllabi. It links to neighbouring topics Pumps, Residential heating appliances, so understanding it makes those chapters shorter.
In everyday life
Look for High efficiency glandless circulating pump outside the textbook — in sport, cooking, traffic, electronics or the sky above you. An example you found yourself is remembered far longer than one you were given.

Affiliate

Preply — study more efficiently by working with a personal tutor. 50% off.

How to study High efficiency glandless circulating pump in 20 minutes

  1. Read the reference excerpt below once, without taking notes.
  2. Close the page and write down what High efficiency glandless circulating pump means in your own words.
  3. Compare your version with the excerpt and mark what you missed.
  4. Work through the three examples above with pen and paper.
  5. Explain High efficiency glandless circulating pump out loud to somebody else — or to Teacher Smith in the lgStudy chat.

Frequently asked questions

What is High efficiency glandless circulating pump in simple terms?

A high efficiency glandless circulating pump is a component of a heating and air conditioning system that allows the system to perform with increased efficiency while significantly reducing the system's electrical usage. Description The pump is primarily composed of an electronically commutated syn…

Why does High efficiency glandless circulating pump matter?

Because it connects several science ideas at once: it gives you a definition you can apply, a quantity you can calculate, and a way to check whether a result is plausible.

How should I study High efficiency glandless circulating pump?

Read the excerpt, restate it from memory, then work through the examples and applications listed on this page. The five-step study plan above takes about twenty minutes.

What does this page cover?

It gives you a compact reference excerpt plus original lgStudy explanations, examples, applications and study material on High efficiency glandless circulating pump.

Tags

  • Pumps
  • Residential heating appliances

Keep exploring