ITU-R 468 (originally defined in CCIR recommendation 468-4, therefore formerly also known as CCIR weighting; sometimes referred to as CCIR-1k) is a standard relating to noise measurement, widely used when measuring noise in audio systems. The standard, now referred to as ITU-R BS.468-4, defines a weighting filter curve, together with a quasi-peak rectifier having special characteristics as defined by specified tone-burst tests. It is currently maintained by the International Telecommunication Union who took it over from the CCIR. It is used especially in the UK, Europe, and former countries of the British Empire such as Australia and South Africa. It is less well known in the USA where A-weighting has always been used. M-weighting is a closely related filter, an offset version of the same curve, without the quasi-peak detector.
Explanation The A-weighting curve was based on the 40 phon equal-loudness contour derived initially by Fletcher and Munson (1933). Originally incorporated into an ANSI standard for sound level meters, A-weighting was intended for measurement of the audibility of sounds by themselves. It was never specifically intended for the measurement of the more random (near-white or pink) noise in electronic equipment, though has been used for this purpose by most microphone manufacturers since the 1970s. The human ear responds quite differently to clicks and bursts of random noise, and it is this difference that gave rise to the CCIR-468 weighting curve (now supported as an ITU standard), which together with quasi-peak measurement (rather than the rms measurement used with A-weighting) became widely used by broadcasters throughout Britain, Europe, and former British Commonwealth countries, where engineers were heavily influenced by BBC test methods. Telephone companies worldwide have also used methods similar to ITU-R 468 weighting with quasi-peak measurement to describe objectionable interference induced in one telephone circuit by switching transients in another.
History
Original research Developments in the 1960s, in particular the spread of FM broadcasting and the development of the compact audio cassette with Dolby-B Noise Reduction, alerted engineers to the need for a weighting curve that gave subjectively meaningful results on the typical random noise that limited the performance of broadcast circuits, equipment and radio circuits. A-weighting was not giving consistent results, especially on FM radio transmissions and Compact Cassette recording where preemphasis of high frequencies was resulting in increased noise readings that did not correlate with subjective effect. Early efforts to produce a better weighting curve led to a DIN standard that was adopted for European Hi-Fi equipment measurement for a while. Experiments in the BBC led to BBC Research Department Report EL-17, The Assessment of Noise in Audio Frequency Circuits, in which experiments on numerous test subjects were reported, using a variety of noises ranging from clicks to tone-bursts to pink noise. Subjects were asked to compare these with a 1 kHz tone, and final scores were then compared with measured noise levels using various combinations of weighting filter and quasi-peak detector then in existence (such as those defined in a now discontinued German DIN standard). This led to the CCIR-468 standard which defined a new weighting curve and quasi-peak rectifier. The origin of the current ITU-R 468 weighting curve can be traced to 1956. The 1968 BBC EL-17 report discusses several weighting curves, including one identified as D.P.B. which was chosen as superior to the alternatives: A.S.A, C.C.I.F and O.I.R.T. The report's graph of the DPB curve is identical to that of the ITU-R 468 curve, except that the latter extends to slightly lower and higher frequencies. The BBC report states that this curve was given in a "contribution by the D.B.P. (The Telephone Administration of the Federal German Republic) in the Red Book Vol. 1 1957 covering the first plenary assembly of the CCITT (Geneva 1956)". D.B.P. is Deutsche Bundespost, the German post office which provides telephone service in Germany as the GPO does in the UK. The BBC report states "this characteristic is based on subjective tests described by Belger." and cites a 1953 paper by E. Belger. Dolby Laboratories took up the new CCIR-468 weighting for use in measuring noise on their noise reduction systems, both in cinema (Dolby A) and on cassette decks (Dolby B), where other methods of measurement were failing to show up the advantage of such noise reduction. Some Hi-Fi column writers took up 468 weighting enthusiastically, observing that it reflected the roughly 10 dB improvement in noise observed subjectively on cassette recordings when using Dolby B while other methods could indicate an actual worsening in some circumstances, because they did not sufficiently attenuate noise above 10 kHz.
… excerpt ends here. Continue reading the full article.