ArticleslgStudy

science

Infiltration and inflow

Infiltration and inflow is a science topic covered in the lgStudy science library. This page brings together a partial reference excerpt, illustrations, worked examples, real-world applications and a short study plan, so you can understand Infiltration and inflow rather than just read about it. In short: Infiltration and inflow (I/I or I&I) is the process of groundwater, or water from sources other than domestic wastewater, entering sanitary sewers. I/I causes dilution in sanitary sewers, which decreases the efficiency of treatment, and may cause sewage volumes to exceed design capacity.

Infiltration and inflow — main illustration
Infiltration and inflow — illustration

Key takeaways

  • Infiltration and inflow belongs to science; place it in that map before memorising details.
  • Learn the definition first, then one example that makes the definition concrete.
  • Connect Infiltration and inflow to a quantity you can measure, compute or draw — that is where exam questions come from.
  • Reproduce the core statement of Infiltration and inflow from memory before moving on to harder problems.

Reference excerpt

Infiltration and inflow (I/I or I&I) is the process of groundwater, or water from sources other than domestic wastewater, entering sanitary sewers. I/I causes dilution in sanitary sewers, which decreases the efficiency of treatment, and may cause sewage volumes to exceed design capacity. Although inflow is technically different from infiltration, it may be difficult to determine which is causing dilution problems in inaccessible sewers. The United States Environmental Protection Agency considers infiltration and inflow to be combined contributions from both.

Background Early combined sewers used surface runoff to dilute waste from toilets and carry it away from urban areas into natural waterways. Sewage treatment can remove some pollutants from toilet waste, but treatment of diluted flow from combined sewers produces larger volumes of treated sewage with similar pollutant concentrations. Modern sanitary sewers are designed to transport domestic and industrial wastewater directly to treatment facilities without dilution.

Infiltration Groundwater entering sanitary sewers through defective pipe joints and broken pipes is called infiltration. Pipes may leak because of careless installation; they may also be damaged after installation by differential ground movement, heavy vehicle traffic on roadways above the sewer, careless construction practices in nearby trenches, or degradation of the sewer pipe materials. In general, volume of leakage will increase over time. Damaged and broken sewer cleanouts are a major cause of infiltration into municipal sewer systems. Infiltration will occur where local groundwater elevation is higher than the sewer pipe. Gravel bedding materials in sewer pipe trenches act as a French drain. Groundwater flows parallel to the sewer until it reaches the area of damaged pipe. In areas of low groundwater, sewage may exfiltrate into groundwater from a leaking sewer.

Inflow

Water entering sanitary sewers from inappropriate connections is called inflow. Typical sources include sump pumps, roof drains, cellar drains, and yard drains where urban features prevent surface runoff, and storm drains are not conveniently accessible or identifiable. Inflow tends to peak during precipitation events, and causes greater flow variation than infiltration. Peak flows caused by inflow may generate a foul flush of accumulated biofilm and sanitary solids scoured from the dry weather wetted perimeter of oversized sewers during peak flow turbulence. Sources of inflow can sometimes be identified by smoke testing. Smoke is blown into the sewer during dry weather while observers watch for smoke emerging from yards, cellars, or roof gutters.

Significance Dilution of sewage directly increases costs of pumping and chlorination, ozonation, or ultraviolet disinfection. Physical treatment structures including screens and pumps must be enlarged to handle the peak flow. Primary clarifiers must also be enlarged to treat average flows, although primary treatment of peak flows may be accomplished in detention basins. Biological secondary treatment is effective only while the concentration of soluble and colloidal pollutants (typically measured as biochemical oxygen demand or BOD) remains high enough to sustain a population of microorganisms digesting those pollutants. In U.S. federal regulations, secondary treatment is expected to remove 85 percent of soluble and colloidal organic pollutants from sewage containing 200 mg/L BOD. BOD removal by conventional biological secondary treatment becomes less effective with dilution and practically ceases as BOD concentrations entering the treatment facility are diluted below about 20 mg/L. Unremoved organics are potentially converted to disinfection by-products by chemical disinfection prior to discharge.

High rates of infiltration and inflow may make the sanitary sewer incapable of carrying sewage from the design service area. Sewage may back up into the lowest homes during wet weather, or street manholes may overflow.

Correction Smoke test results may not correlate well with flow volumes; although they can identify potential problem locations. Where sewage flow is expected to be relatively uniform, significance of infiltration and inflow may be estimated by comparison of sewage flow at the same point during wet and dry weather or at two sequential points within the sewer system. Small areas with large flow differences can be identified if the sewer system provides adequate measuring locations. It may be necessary to replace a section of sewer line if flow differences cannot be corrected by removing identified connections.

References

Illustrations

Infiltration and inflow: Excessive infiltration and inflow may cause sanitary sewer overflows during wet weather.
Excessive infiltration and inflow may cause sanitary sewer overflows during wet weather.

Worked examples

Example 1 — a first encounter with Infiltration and inflow

Start with the simplest possible case. Write down what Infiltration and inflow claims or describes in one sentence, then invent the smallest concrete situation in which that sentence is true. In science, the smallest case is usually a single object, a single equation or a single measurement. Check that every symbol or term in your sentence has a meaning in that case.

Example 2 — changing one variable

Take the situation from Example 1 and change exactly one quantity: double it, halve it, or set it to zero. Predict what should happen to Infiltration and inflow before you calculate. Comparing your prediction with the result is the fastest way to find out whether you understand the idea or only the words.

Example 3 — an exam-style question

Typical questions about Infiltration and inflow ask you to (a) state it precisely, (b) apply it to given data, and (c) explain a limitation. Practise writing all three answers in under five minutes; the third part is what separates a full-mark answer from an average one.

Applications of Infiltration and inflow

In research
Infiltration and inflow appears in science research whenever the underlying quantities have to be modelled precisely. Papers usually cite it as a starting assumption and then explore where it breaks down.
In technology and industry
Engineering practice reuses Infiltration and inflow in design rules, simulations and safety margins. Knowing the idea lets you read a specification sheet and understand why the numbers look the way they do.
In the classroom
Infiltration and inflow is common in secondary-school and first-year university syllabi. It links to neighbouring topics Sewerage, Water pollution, so understanding it makes those chapters shorter.
In everyday life
Look for Infiltration and inflow outside the textbook — in sport, cooking, traffic, electronics or the sky above you. An example you found yourself is remembered far longer than one you were given.
Ask Teacher Smith questions about this articleOpens your AI tutor with a question about “Infiltration and inflow” →

Affiliate

Preply — study more efficiently by working with a personal tutor. 50% off.

How to study Infiltration and inflow in 20 minutes

  1. Read the reference excerpt below once, without taking notes.
  2. Close the page and write down what Infiltration and inflow means in your own words.
  3. Compare your version with the excerpt and mark what you missed.
  4. Work through the three examples above with pen and paper.
  5. Explain Infiltration and inflow out loud to somebody else — or to Teacher Smith in the lgStudy chat.

Frequently asked questions

What is Infiltration and inflow in simple terms?

Infiltration and inflow (I/I or I&I) is the process of groundwater, or water from sources other than domestic wastewater, entering sanitary sewers. I/I causes dilution in sanitary sewers, which decreases the efficiency of treatment, and may cause sewage volumes to exceed design capacity.

Why does Infiltration and inflow matter?

Because it connects several science ideas at once: it gives you a definition you can apply, a quantity you can calculate, and a way to check whether a result is plausible.

How should I study Infiltration and inflow?

Read the excerpt, restate it from memory, then work through the examples and applications listed on this page. The five-step study plan above takes about twenty minutes.

What does this page cover?

It gives you a compact reference excerpt plus original lgStudy explanations, examples, applications and study material on Infiltration and inflow.

Tags

  • Sewerage
  • Water pollution

Keep exploring