Ion funnel is a science topic covered in the lgStudy science library. This page brings together a partial reference excerpt, illustrations, worked examples, real-world applications and a short study plan, so you can understand Ion funnel rather than just read about it. In short: In mass spectrometry, an ion funnel is a device used to focus a beam of ions using a series of stacked ring electrodes with decreasing inner diameter. A combined radio frequency and fixed electrical potential is applied to the grids.

Ion funnel — main illustration
Ion funnel — illustration

Key takeaways

  • Ion funnel belongs to science; place it in that map before memorising details.
  • Learn the definition first, then one example that makes the definition concrete.
  • Connect Ion funnel to a quantity you can measure, compute or draw — that is where exam questions come from.
  • Reproduce the core statement of Ion funnel from memory before moving on to harder problems.

Reference excerpt

In mass spectrometry, an ion funnel is a device used to focus a beam of ions using a series of stacked ring electrodes with decreasing inner diameter. A combined radio frequency and fixed electrical potential is applied to the grids. In electrospray ionization-mass spectrometry (ESI-MS), ions are created at atmospheric pressure, but are analyzed at subsequently lower pressures. Ions can be lost while they are shuttled from areas of higher to lower pressure due to the transmission process caused by a phenomenon called Joule expansion or “free-jet expansion.” These ion clouds expand outward, which limits the amount of ions that reach the detector, so fewer ions are analyzed. The ion funnel refocuses and transmits ions efficiently from those areas of high to low pressure.

History The first ion funnel was created in 1997 in the Environmental Molecular Sciences Laboratory Pacific Northwest National Laboratory by the researchers in Richard D. Smith's lab. The ion funnel was implemented to replace the ion transmission-limited skimmer for more efficient ion capture in an ESI source. Many characteristics of the ion funnel are attributed to the stacked ring ion guide, however, the disks of an ion funnel vary in diameter down its long axis. There is a portion at the base of the ion funnel in which a series of cylindrical ring electrodes have decreasing diameters, which enables the ion cloud entering the ion funnel to be spatially dispersed. This allows for efficient transfer of the ion cloud through the conductance limiting orifice at the exit as the ion cloud becomes focused to a much smaller radial size. The DC electric field serves to push ions through the funnel. For positive ions, the front plate of the funnel has the most positive DC voltage, and subsequent plates have gradually decreasing DC components, providing added control. RF and DC electric fields are co-applied with a pseudopotential created with alternating RF polarities on adjacent electrodes. This “pseudo-potential” radially confines ions and causes instability in ions with a lower m/z (mass to charge ratio) while ions with a higher m/z are focused to the center of the funnel. The initial ion funnel design used in the Smith research lab proved inefficient for collecting ions with low m/z. Simulations suggest that decreasing the spacing between the lenses so that they are less than the diameter of the smallest ring electrode could be a plausible solution to this problem. Another issue with the design is that the funnel is susceptible to noise with fast neutrals and charged droplets at many atmospheric interfaces during the initial vacuum phase. Modifications increase the efficiency and signal to noise ratio of the ion funnel. Some of the earliest ion funnels struggled to control gas flow as the pressure in the ion vacuum chamber was not uniform due to gas dynamic effects. The pressure at the funnel's exit was estimated to be 2 to 3 times higher than the pressure from the pressure gauge. The higher pressure required greater pumping in downstream vacuum chambers to compensate for the larger injection of gas. The discrepancy between the measured pressure and the pressure at the exit of the funnel was caused by the a sizable portion of the supersonic gas jet from the injector continuing beyond the Mach disk or shock diamond at the beginning of the funnel and continuing through until the end. The most effective resolution is the us of a jet disrupter that consists of a 9 mm diameter brass disk suspended perpendicular to the gas flow in the center of the ion funnel.

Applications

Mass spectrometry Ion funnels are frequently used in mass spectroscopy devices to collect ions from an ionization source. Previous devices lacking an ion funnel often lost ions during the transition from ionization source to the detector of the mass spectrometer. This loss was due to the increasing number of collisions undergone by ions with other gas molecules present in the atmosphere. The introduction of the ion funnel greatly reduced the amount of ions lost during experiments by guiding ions towards a desired destination, and through modification of the number of inlets is also able to increases sensitivity of measurements taken by the mass spectrometer. Multiple inlets allow multiple electrospray emitters, reducing the flow through each individual emitter. This creates many highly efficient electrosprays at low flow rates. Multiple inlets also improve sensitivity, with a linearly arranged 19 electrospray emitter coupled to 19 inlets operating at 18 Torr giving a nine-fold increase compared to a single inlet.

Proton transfer reaction chamber Proton transfer reaction mass spectrometry has traditionally used drift tubes as ion traps. However, radio frequency ion funnels offer an attractive alternative, as they improve compound specific sensitivity significantly. This is due to increasing the effective reaction time and focusing the ions. The same pressure ranges are required for ion funnels and drift tubes, so the technology is not difficult to implement. Ion funnels have been shown to favor transmission of ions with high m/z.

Breath analysis Breath analysis is a convenient and non-invasive way to detect chemicals in a bodily system such as alcohol content to determine intoxication, monitor the levels of anesthetics in the body during surgical procedures, and identify performance-enhancing substances in the system of athletes. However, conventional techniques are ineffective at low concentrations. An electrospray ionization interface assisted by an ion funnel used in a linear trap quadrupole Fourier-transform ion cyclotron resonance mass spectrometer was shown to greatly increase sensitivity with high resolution.

See also Electrostatic lens Reflectron

References

Illustrations

Ion funnel: A picture of an ion funnel attached to an instrument.
A picture of an ion funnel attached to an instrument.
Ion funnel: A side view of an ion funnel. Each electrode (metal disk) is visible from the outside.
A side view of an ion funnel. Each electrode (metal disk) is visible from the outside.
Ion funnel: A top-down view of an ion funnel. The decreasing radii of the electrodes is visible from this angle.
A top-down view of an ion funnel. The decreasing radii of the electrodes is visible from this angle.

Worked examples

Example 1 — a first encounter with Ion funnel

Start with the simplest possible case. Write down what Ion funnel claims or describes in one sentence, then invent the smallest concrete situation in which that sentence is true. In science, the smallest case is usually a single object, a single equation or a single measurement. Check that every symbol or term in your sentence has a meaning in that case.

Example 2 — changing one variable

Take the situation from Example 1 and change exactly one quantity: double it, halve it, or set it to zero. Predict what should happen to Ion funnel before you calculate. Comparing your prediction with the result is the fastest way to find out whether you understand the idea or only the words.

Example 3 — an exam-style question

Typical questions about Ion funnel ask you to (a) state it precisely, (b) apply it to given data, and (c) explain a limitation. Practise writing all three answers in under five minutes; the third part is what separates a full-mark answer from an average one.

Applications of Ion funnel

In research
Ion funnel appears in science research whenever the underlying quantities have to be modelled precisely. Papers usually cite it as a starting assumption and then explore where it breaks down.
In technology and industry
Engineering practice reuses Ion funnel in design rules, simulations and safety margins. Knowing the idea lets you read a specification sheet and understand why the numbers look the way they do.
In the classroom
Ion funnel is common in secondary-school and first-year university syllabi. It links to neighbouring topics Ions, Mass spectrometry, so understanding it makes those chapters shorter.
In everyday life
Look for Ion funnel outside the textbook — in sport, cooking, traffic, electronics or the sky above you. An example you found yourself is remembered far longer than one you were given.
Ask Teacher Smith questions about this articleOpens your AI tutor with a question about “Ion funnel” →

Affiliate

Preply — study more efficiently by working with a personal tutor. 50% off.

How to study Ion funnel in 20 minutes

  1. Read the reference excerpt below once, without taking notes.
  2. Close the page and write down what Ion funnel means in your own words.
  3. Compare your version with the excerpt and mark what you missed.
  4. Work through the three examples above with pen and paper.
  5. Explain Ion funnel out loud to somebody else — or to Teacher Smith in the lgStudy chat.

Frequently asked questions

What is Ion funnel in simple terms?

In mass spectrometry, an ion funnel is a device used to focus a beam of ions using a series of stacked ring electrodes with decreasing inner diameter. A combined radio frequency and fixed electrical potential is applied to the grids.

Why does Ion funnel matter?

Because it connects several science ideas at once: it gives you a definition you can apply, a quantity you can calculate, and a way to check whether a result is plausible.

How should I study Ion funnel?

Read the excerpt, restate it from memory, then work through the examples and applications listed on this page. The five-step study plan above takes about twenty minutes.

What does this page cover?

It gives you a compact reference excerpt plus original lgStudy explanations, examples, applications and study material on Ion funnel.