ArticleslgStudy

science

Linear sweep voltammetry

Linear sweep voltammetry is a science topic covered in the lgStudy science library. This page brings together a partial reference excerpt, illustrations, worked examples, real-world applications and a short study plan, so you can understand Linear sweep voltammetry rather than just read about it. In short: In analytical chemistry, linear sweep voltammetry is a method of voltammetry where the current at a working electrode is measured while the potential between the working electrode and a reference electrode is swept linearly in time. Oxidation or reduction of species is registered as a peak or trough in the current signal at the potential at which the species begins to be oxidized or reduced.

Linear sweep voltammetry — main illustration
Linear sweep voltammetry — illustration

Key takeaways

  • Linear sweep voltammetry belongs to science; place it in that map before memorising details.
  • Learn the definition first, then one example that makes the definition concrete.
  • Connect Linear sweep voltammetry to a quantity you can measure, compute or draw — that is where exam questions come from.
  • Reproduce the core statement of Linear sweep voltammetry from memory before moving on to harder problems.

Reference excerpt

In analytical chemistry, linear sweep voltammetry is a method of voltammetry where the current at a working electrode is measured while the potential between the working electrode and a reference electrode is swept linearly in time. Oxidation or reduction of species is registered as a peak or trough in the current signal at the potential at which the species begins to be oxidized or reduced.

Experimental method

The experimental setup for linear sweep voltammetry utilizes a potentiostat and a three-electrode setup to deliver a potential to a solution and monitor its change in current. The three-electrode setup consists of a working electrode, an auxiliary electrode, and a reference electrode. The potentiostat delivers the potentials through the three-electrode setup. A potential, E, is delivered through the working electrode. The slope of the potential vs. time graph is called the scan rate and can range from mV/s to 1,000,000 V/s. The working electrode is one of the electrodes at which the oxidation/reduction reactions occur—the processes that occur at this electrode are the ones being monitored. The auxiliary electrode (or counter electrode) is the one at which a process opposite from the one taking place at the working electrode occurs. The processes at this electrode are not monitored. The equation below gives an example of a reduction occurring at the surface of the working electrode. Es is the reduction potential of A (if the electrolyte and the electrode are in their standard conditions, then this potential is a standard reduction potential). As E approaches Es, the current on the surface increases, and when E = Es, the concentration of A equals that of the oxidized/reduced A at the surface ([A] = [A−]). As the molecules on the surface of the working electrode are oxidized/reduced, they move away from the surface and new molecules come into contact with the surface of the working electrode. The flow of electrons into or out of the electrode causes the current. The current is a direct measure of the rate at which electrons are being exchanged through the electrode-electrolyte interface. When this rate becomes higher than the rate at which the oxidizing or reducing species can diffuse from the bulk of the electrolyte to the surface of the electrode, the current reaches a plateau or exhibits a peak:

A + e − ↽ − − ⇀ A − , E s = 0.00 V {\displaystyle {\ce {A + e- <=> A-}},\ E_{s}=0.00V}

Reduction of molecule A at the surface of the working electrode. The auxiliary and reference electrode work in unison to balance out the charge added or removed by the working electrode. The auxiliary electrode balances the working electrode, but in order to know how much potential it has to add or remove it relies on the reference electrode. The reference electrode has a known reduction potential. The auxiliary electrode tries to keep the reference electrode at a certain reduction potential and to do this it has to balance the working electrode.

Characterization Linear sweep voltammetry can identify unknown species and determine the concentration of solutions. E1/2 can be used to identify the unknown species while the height of the limiting current can determine the concentration. The sensitivity of current changes vs. voltage can be increased by increasing the scan rate. Higher potentials per second result in more oxidation/reduction of a species at the surface of the working electrode.

Variations For reversible reactions cyclic voltammetry can be used to find information about the forward reaction and the reverse reaction. Like linear sweep voltammetry, cyclic voltammetry applies a linear potential over time and at a certain potential the potentiostat will reverse the potential applied and sweep back to the beginning point. Cyclic voltammetry provides information about the oxidation and reduction reactions.

Applications While cyclic voltammetry is applicable to most cases where linear sweep voltammetry is used, there are some instances where linear sweep voltammetry is more useful. In cases where the reaction is irreversible cyclic voltammetry will not give any additional data that linear sweep voltammetry would give us. In one example, linear voltammetry was used to examine direct methane production via a biocathode. Since the production of methane from CO2 is an irreversible reaction, cyclic voltammetry did not present any distinct advantage over linear sweep voltammetry. This group found that the biocathode produced higher current densities than a plain carbon cathode and that methane can be produced from a direct electric current without the need of hydrogen gas.

See also Voltammetry Cyclic voltammetry Electroanalytical methods

References

Illustrations

Linear sweep voltammetry: Linear potential sweep
Linear potential sweep
Linear sweep voltammetry: Comparison of the current response of a platinum disc electrode in 1 M sulphuric acid given by linear sweep cyclic voltammetry and staircase cyclic voltammetry methods. Staircase voltammetry suppresses the non-faradaic adsorption of hydrogen.
Comparison of the current response of a platinum disc electrode in 1 M sulphuric acid given by linear sweep cyclic voltammetry and staircase cyclic voltammetry methods. Staircase voltammetry suppresses the non-faradaic adsorption of hydrogen.

Worked examples

Example 1 — a first encounter with Linear sweep voltammetry

Start with the simplest possible case. Write down what Linear sweep voltammetry claims or describes in one sentence, then invent the smallest concrete situation in which that sentence is true. In science, the smallest case is usually a single object, a single equation or a single measurement. Check that every symbol or term in your sentence has a meaning in that case.

Example 2 — changing one variable

Take the situation from Example 1 and change exactly one quantity: double it, halve it, or set it to zero. Predict what should happen to Linear sweep voltammetry before you calculate. Comparing your prediction with the result is the fastest way to find out whether you understand the idea or only the words.

Example 3 — an exam-style question

Typical questions about Linear sweep voltammetry ask you to (a) state it precisely, (b) apply it to given data, and (c) explain a limitation. Practise writing all three answers in under five minutes; the third part is what separates a full-mark answer from an average one.

Applications of Linear sweep voltammetry

In research
Linear sweep voltammetry appears in science research whenever the underlying quantities have to be modelled precisely. Papers usually cite it as a starting assumption and then explore where it breaks down.
In technology and industry
Engineering practice reuses Linear sweep voltammetry in design rules, simulations and safety margins. Knowing the idea lets you read a specification sheet and understand why the numbers look the way they do.
In the classroom
Linear sweep voltammetry is common in secondary-school and first-year university syllabi. It links to neighbouring topics Electroanalytical methods, so understanding it makes those chapters shorter.
In everyday life
Look for Linear sweep voltammetry outside the textbook — in sport, cooking, traffic, electronics or the sky above you. An example you found yourself is remembered far longer than one you were given.

Affiliate

Preply — study more efficiently by working with a personal tutor. 50% off.

How to study Linear sweep voltammetry in 20 minutes

  1. Read the reference excerpt below once, without taking notes.
  2. Close the page and write down what Linear sweep voltammetry means in your own words.
  3. Compare your version with the excerpt and mark what you missed.
  4. Work through the three examples above with pen and paper.
  5. Explain Linear sweep voltammetry out loud to somebody else — or to Teacher Smith in the lgStudy chat.

Frequently asked questions

What is Linear sweep voltammetry in simple terms?

In analytical chemistry, linear sweep voltammetry is a method of voltammetry where the current at a working electrode is measured while the potential between the working electrode and a reference electrode is swept linearly in time. Oxidation or reduction of species is registered as a peak or troug…

Why does Linear sweep voltammetry matter?

Because it connects several science ideas at once: it gives you a definition you can apply, a quantity you can calculate, and a way to check whether a result is plausible.

How should I study Linear sweep voltammetry?

Read the excerpt, restate it from memory, then work through the examples and applications listed on this page. The five-step study plan above takes about twenty minutes.

What does this page cover?

It gives you a compact reference excerpt plus original lgStudy explanations, examples, applications and study material on Linear sweep voltammetry.

Tags

  • Electroanalytical methods

Keep exploring