Luminous intensity is a physics topic covered in the lgStudy science library. This page brings together a partial reference excerpt, illustrations, worked examples, real-world applications and a short study plan, so you can understand Luminous intensity rather than just read about it. In short: In photometry, luminous intensity is a measure of the wavelength-weighted power emitted by a light source in a particular direction per unit solid angle, based on the luminosity function, a standardized model of the sensitivity of the human eye. The SI unit of luminous intensity is the candela (cd), an SI base unit.

Luminous intensity — main illustration
Luminous intensity — illustration

Key takeaways

  • Luminous intensity belongs to physics; place it in that map before memorising details.
  • Learn the definition first, then one example that makes the definition concrete.
  • Connect Luminous intensity to a quantity you can measure, compute or draw — that is where exam questions come from.
  • Reproduce the core statement of Luminous intensity from memory before moving on to harder problems.

Reference excerpt

In photometry, luminous intensity is a measure of the wavelength-weighted power emitted by a light source in a particular direction per unit solid angle, based on the luminosity function, a standardized model of the sensitivity of the human eye. The SI unit of luminous intensity is the candela (cd), an SI base unit.

Measurement Photometry deals with the measurement of visible light as perceived by human eyes. The human eye can only see light in the visible spectrum and has different sensitivities to light of different wavelengths within the spectrum. When adapted for bright conditions (photopic vision), the eye is most sensitive to yellow-green light at 555 nm. Light with the same radiant intensity at other wavelengths has a lower luminous intensity. The curve which represents the response of the human eye to light is a defined standard function y(λ) or V(λ) established by the International Commission on Illumination (CIE, for Commission Internationale de l'Éclairage) and standardized in collaboration with the ISO. Luminous intensity of artificial light sources is typically measured using a goniophotometer outfitted with a photometer or a spectroradiometer.

Relationship to other measures

Luminous intensity should not be confused with another photometric unit, luminous flux, which is the total perceived power emitted in all directions. Luminous intensity is the perceived power per unit solid angle. If a lamp has a 1 lumen bulb and the optics of the lamp are set up to focus the light evenly into a 1 steradian beam, then the beam would have a luminous intensity of 1 candela. If the optics were changed to concentrate the beam into 1/2 steradian then the source would have a luminous intensity of 2 candela. The resulting beam is narrower and brighter, though its luminous flux remains unchanged. Luminous intensity is also not the same as the radiant intensity, the corresponding objective physical quantity used in the measurement science of radiometry.

Units Like other SI base units, the candela has an operational definition—it is defined by the description of a physical process that will produce one candela of luminous intensity. By definition, if one constructs a light source that emits monochromatic green light with a frequency of 540 THz, and that has a radiant intensity of 1/683 watts per steradian in a given direction, that light source will emit one candela in the specified direction. The frequency of light used in the definition corresponds to a wavelength in a vacuum of 555 nm, which is near the peak of the eye's response to light. If the 1 candela source emitted uniformly in all directions, the total radiant flux would be about 18.40 mW, since there are 4π steradians in a sphere. A typical modern candle produces very roughly one candela while releasing heat at roughly 80 W. Prior to the definition of the candela, a variety of units for luminous intensity were used in various countries. These were typically based on the brightness of the flame from a "standard candle" of defined composition, or the brightness of an incandescent filament of specific design. One of the best-known of these standards was the English standard: candlepower. One candlepower was the light produced by a pure spermaceti candle weighing one sixth of a pound and burning at a rate of 120 grains per hour. Germany, Austria, and Scandinavia used the Hefnerkerze, a unit based on the output of a Hefner lamp. In 1881, Jules Violle proposed the Violle as a unit of luminous intensity, and it was notable as the first unit of light intensity that did not depend on the properties of a particular lamp. All of these units were superseded by the definition of the candela.

Usage

The luminous intensity for monochromatic light of a particular wavelength λ is given by

I v = 683 ⋅ y ¯ ( λ ) ⋅ I e , {\displaystyle I_{\mathrm {v} }=683\cdot {\overline {y}}(\lambda )\cdot I_{\mathrm {e} },}

where

Iv is the luminous intensity in candelas (cd), Ie is the radiant intensity in watts per steradian (W/sr),

y ¯ ( λ ) {\textstyle {\overline {y}}(\lambda )} is the standard luminosity function. If more than one wavelength is present (as is usually the case), one must sum or integrate over the spectrum of wavelengths present to get the luminous intensity:

I v = 683 ∫ 0 ∞ y ¯ ( λ ) ⋅ ∂ I e ∂ λ d λ . {\displaystyle I_{\mathrm {v} }=683\int _{0}^{\infty }{\overline {y}}(\lambda )\cdot {\frac {\partial I_{\mathrm {e} }}{\partial \lambda }}\,d\lambda .}

See also Brightness International System of Quantities Radiance

References

Curve data

Illustrations

Luminous intensity: Photopic (black) and scotopic (green) luminosity functions.[c 1] The photopic includes the CIE 1931 standard[c 2][c 3] (solid), the Judd–Vos 1978 modified data[c 4] (dashed), and the Sharpe, Stockman, Jagla & Jägle 2005 data[c 5] (dotted). The horizontal axis is wavelength in nm.
Photopic (black) and scotopic (green) luminosity functions.[c 1] The photopic includes the CIE 1931 standard[c 2][c 3] (solid), the Judd–Vos 1978 modified data[c 4] (dashed), and the Sharpe, Stockman, Jagla & Jägle 2005 data[c 5] (dotted). The horizontal axis is wavelength in nm.

Worked examples

Example 1 — a first encounter with Luminous intensity

Start with the simplest possible case. Write down what Luminous intensity claims or describes in one sentence, then invent the smallest concrete situation in which that sentence is true. In physics, the smallest case is usually a single object, a single equation or a single measurement. Check that every symbol or term in your sentence has a meaning in that case.

Example 2 — changing one variable

Take the situation from Example 1 and change exactly one quantity: double it, halve it, or set it to zero. Predict what should happen to Luminous intensity before you calculate. Comparing your prediction with the result is the fastest way to find out whether you understand the idea or only the words.

Example 3 — an exam-style question

Typical questions about Luminous intensity ask you to (a) state it precisely, (b) apply it to given data, and (c) explain a limitation. Practise writing all three answers in under five minutes; the third part is what separates a full-mark answer from an average one.

Applications of Luminous intensity

In research
Luminous intensity appears in physics research whenever the underlying quantities have to be modelled precisely. Papers usually cite it as a starting assumption and then explore where it breaks down.
In technology and industry
Engineering practice reuses Luminous intensity in design rules, simulations and safety margins. Knowing the idea lets you read a specification sheet and understand why the numbers look the way they do.
In the classroom
Luminous intensity is common in secondary-school and first-year university syllabi. It links to neighbouring topics Electromagnetic quantities, Photometry, SI base quantities, so understanding it makes those chapters shorter.
In everyday life
Look for Luminous intensity outside the textbook — in sport, cooking, traffic, electronics or the sky above you. An example you found yourself is remembered far longer than one you were given.

Affiliate

Preply — study more efficiently by working with a personal tutor. 50% off.

How to study Luminous intensity in 20 minutes

  1. Read the reference excerpt below once, without taking notes.
  2. Close the page and write down what Luminous intensity means in your own words.
  3. Compare your version with the excerpt and mark what you missed.
  4. Work through the three examples above with pen and paper.
  5. Explain Luminous intensity out loud to somebody else — or to Teacher Smith in the lgStudy chat.

Frequently asked questions

What is Luminous intensity in simple terms?

In photometry, luminous intensity is a measure of the wavelength-weighted power emitted by a light source in a particular direction per unit solid angle, based on the luminosity function, a standardized model of the sensitivity of the human eye. The SI unit of luminous intensity is the candela (cd)…

Why does Luminous intensity matter?

Because it connects several physics ideas at once: it gives you a definition you can apply, a quantity you can calculate, and a way to check whether a result is plausible.

How should I study Luminous intensity?

Read the excerpt, restate it from memory, then work through the examples and applications listed on this page. The five-step study plan above takes about twenty minutes.

What does this page cover?

It gives you a compact reference excerpt plus original lgStudy explanations, examples, applications and study material on Luminous intensity.

Tags

  • Electromagnetic quantities
  • Photometry
  • SI base quantities
  • Scalar physical quantities