Mechanosensitive channels (MSCs), mechanosensitive ion channels or stretch-gated ion channels are membrane proteins capable of responding to mechanical stress over a wide dynamic range of external mechanical stimuli. They are present in the membranes of organisms from the three domains of life: bacteria, archaea, and eukarya. They are the sensors for a number of systems including the senses of touch, hearing and balance, as well as participating in cardiovascular regulation and osmotic homeostasis (e.g. thirst). The channels vary in selectivity for the permeating ions from nonselective between anions and cations in bacteria, to cation selective allowing passage Ca2+, K+ and Na+ in eukaryotes, and highly selective K+ channels in bacteria and eukaryotes. All organisms, and apparently all cell types, sense and respond to mechanical stimuli. MSCs function as mechanotransducers capable of generating both electrical and ion flux signals as a response to external or internal stimuli. Under extreme turgor in bacteria, non selective MSCs such as MSCL and MSCS serve as safety valves to prevent lysis. In specialized cells of the higher organisms, other types of MSCs are probably the basis of the senses of hearing and touch and sense the stress needed for muscular coordination. However, none of these channels have been cloned. MSCs also allow plants to distinguish up from down by sensing the force of gravity. MSCs are not pressure-sensitive, but sensitive to local stress, most likely tension in the surrounding lipid bilayer.
History Mechanosensitive channels were discovered in 1983 in the skeletal muscle of embryonic chicks by Falguni Guharay and Frederick Sachs. They were also observed (pub. 1986) in Xenopus oocytes, and frequently studied since that time. Since then, MSCs have been found in cells from bacteria to humans: they are now known to be present in all three domains of life (Archaea, Bacteria and Eukarya, incl. plants and fungi). In the decades since the discovery of MS, the understanding of their structure and function has increased greatly, and several have been cloned. Specifically, the cloned eukaryotic mechanosensitive channels include the K+ selective 2P domain channels and the recently cloned cation selective PIEZO family (PIEZO1 and PIEZO2).
Classification MSCs can be classified based on the type of ion to which they are permeable:
Cation Selective MSCs: As the name suggests, they exhibit a selective permeability for positive ions with the most selective channels being those for K+. The most common eukaryotic MSCs are cation selective passing Na+, K+ and Ca2+ but not Mg2+. They have a single channel conductance range (25-35 pS) and they are blocked by trivalent ion Gadolinium. The K+ selective MSCs such as TREK-1 are not blocked by Gd3+. Anion Channels: they exhibit a significant permeability for negative ions, and are not predominant as cation MS. They have a large conductance range (> 300pS). Non Selective ion channels: As the name indicates, they do not differentiate between positive and negative channels those are more common to Archaea and Bacteria, but rarely found in Eukarya. Broadly, most MSCs can be classified as lipid-gated channels.
Functions For a protein to be considered mechanosensitive, it must respond to a mechanical deformation of the membrane. Mechanical deformations can include changes in the tension, thickness, or curvature of the membrane. Mechanosensitive channels respond to membrane tension by altering their conformation between an open state and a closed state. One type of mechanically sensitive ion channel activates specialized sensory cells, such as cochlear hair cells and some touch sensory neurons, in response to forces applied to proteins. Stretch-activated ion channels are required for the initial formation of an action potential from a mechanical stimulus, for example by the mechanoreceptors in vibrissae (whiskers) of some animals such as rodents. Afferent nerve fibers responsible for sensory stimulus detection and feedback are especially sensitive to stimulation. This results from the specialized mechanoreceptor cells that are superimposed upon the afferent nerve fibers. Stretch-activated ion channels are located on these mechanoreceptor cells and serve to lower the action potential threshold, thus making the afferent nerves more sensitive to stimulation. Afferent nerve endings without mechanoreceptor cells are called free nerve endings. They are less sensitive than the encapsulated afferent fibers and generally function in the perception of pain. Stretch-activated ion channels are responsible for many bodily functions in mammals. In the skin they are responsible for sensing vibration, pressure sensation, stretch, touch, and light touch. They are expressed in sensory modalities including taste, hearing, smell, heat sensation, volume control, and vision. They can also regulate internal functions of our body including, but not limited to, osmotic pressure in cells, blood pressure in veins and arteries, micturition, and heart electrophysiology and contractility. In addition to these functionalities, stretch-activated ion channels have also been found to be involved with balance and proprioceptive sensation. Channels that have traditionally been known as just "voltage-" or "ligand-gated" have also been found to be mechanically sensitive as well. Channels exhibit mechanical sensitivity as a general property. However, mechanical stress affects various types of channels in different ways. Voltage and ligand gated channels can be modified slightly by mechanical stimulation, which might change their responsiveness or permeability slightly, but they still respond primarily to voltage or ligands, respectively.
… excerpt ends here. Continue reading the full article.


![Mechanosensitive channels: Gating Mechanism of MS.Stretch activated model, tension in the lipid bilayer triggers conformational changes which open the channel. Figure adapted from Lumpkin et al.[67]](https://upload.wikimedia.org/wikipedia/commons/thumb/3/3c/Stretch_model%2C.jpg/500px-Stretch_model%2C.jpg?utm_source=en.wikipedia.org&utm_campaign=parser&utm_content=thumbnail)
![Mechanosensitive channels: Gating Mechanism of MSC:Spring-like tether model - The tethers are attached to the channel proteins and are connected to the cytoskeleton. The tethers act like spring mechanisms of a shutter. Figure adapted from Lumpkin et al.[67]](https://upload.wikimedia.org/wikipedia/commons/thumb/3/3e/Spring-like_model.jpg/500px-Spring-like_model.jpg?utm_source=en.wikipedia.org&utm_campaign=parser&utm_content=thumbnail)


