ArticleslgStudy

science

Penile plethysmography

Penile plethysmography is a science topic covered in the lgStudy science library. This page brings together a partial reference excerpt, illustrations, worked examples, real-world applications and a short study plan, so you can understand Penile plethysmography rather than just read about it. In short: Penile plethysmography (PPG) or phallometry is a measurement of blood flow to the penis, typically used as a proxy for measurement of sexual arousal. The most commonly reported methods of conducting penile plethysmography involves the measurement of the circumference of the penis with a mercury-in-rubber or electromechanical strain gauge, or the volume of the penis with an airtight cylinder and inflatable cuff at th…

Penile plethysmography — main illustration
Penile plethysmography — illustration

Key takeaways

  • Penile plethysmography belongs to science; place it in that map before memorising details.
  • Learn the definition first, then one example that makes the definition concrete.
  • Connect Penile plethysmography to a quantity you can measure, compute or draw — that is where exam questions come from.
  • Reproduce the core statement of Penile plethysmography from memory before moving on to harder problems.

Reference excerpt

Penile plethysmography (PPG) or phallometry is a measurement of blood flow to the penis, typically used as a proxy for measurement of sexual arousal. The most commonly reported methods of conducting penile plethysmography involves the measurement of the circumference of the penis with a mercury-in-rubber or electromechanical strain gauge, or the volume of the penis with an airtight cylinder and inflatable cuff at the base of the penis. Corpora cavernosa nerve penile plethysmographs measure changes in response to inter-operative electric stimulation during surgery. The volumetric procedure was invented by Kurt Freund and is considered to be particularly sensitive at low arousal levels. The easier to use circumferential measures are more widely used, however, and more common in studies using erotic film stimuli. A corresponding device in women is the vaginal photoplethysmograph. For sexual offenders it is typically used to determine the level of sexual arousal as the subject is exposed to sexually suggestive content, such as pictures, movies or audio, although some have argued that phallometry is not always appropriate for the evaluation of sexual preferences or treatment effects. A 1998 large-scale meta-analytic review of the scientific reports demonstrated that phallometric response to stimuli depicting children, though only having a .32 correlation with future sex offending (accounting for approximately 10% of the variance), had the highest accuracy among methods of identifying which sexual offenders will go on to commit new sexual crimes. (None of the methods were strong predictors with most accounting for far less than 10% of the variance). In prostatectomy nerve-sparing surgery, the surgeon applies a mild electrical stimulation near the cavernous nerves of penis to verify their locations and avoid operative trauma. Damage to these difficult-to-see nerves can cause erectile dysfunction outcomes. At the surgery's conclusion, the electrical stimulation penile plethysmograph result is a prognosis which helps to manage the erectile function outcomes earlier than the many months required for recovery.

Types

There are two types of penile plethysmograph:

Volumetric air chamber When this is placed over the subject's penis, as tumescence increases, the air displaced is measured. Circumferential transducer This uses a mercury-in-rubber or indium/gallium-in-rubber ring or electromechanical strain gauge and is placed around the shaft of the subject's penis to measure changes in circumference. The circumferential type is more common, but the volumetric method is believed to be more accurate at low arousal levels. Significant suppliers of PPG machines include Behavioral Technology Inc. and Medical Monitoring Systems. The device is known to be used in Brazil, Britain, Canada, China, Czech Republic, Hong Kong, New Zealand, Norway, Slovak Republic, Spain, and the United States. The surgical machine is supplied as CaverMap by Blue Torch Medical Technology, Inc. A roughly equivalent procedure for women, vaginal photoplethysmography, measures blood through the walls of the vagina, which researchers claim increases during sexual arousal.

Methodology Exact procedures can vary, but in one study a seventeen-year-old male sex offender was, at the start of each daily session, privately fitted with a Parks Medical Electronics mercury strain gauge attached to his penis and worn under trousers and underwear. The device had previously been calibrated with measurements from his penis in its flaccid state and at full erection as achieved through masturbation. This device was connected to a microprocessor, a battery pack, and a strain gauge amplifier, all of which were kept discreetly in a fanny pack. He was then driven daily to a college campus for multiple sessions to assess his sexual attraction to women and men, who were about 30–100 feet away from him. While remaining in a parked car, he was instructed to focus on either a specific woman or a specific man in the setting, imagine himself having sex with them, and allow himself to become sexually aroused if he was so inclined. The device then measured the percentage of full erection that he achieved. This was repeated over a period of 24 days, with the results showing a significantly greater level of attraction to women, especially when research staff were discreetly absent.

History The original volumetric was developed during the 1950s by Kurt Freund in then-Czechoslovakia. Freund later wrote, "In the early fifties homosexual interaction was still an indictable offense in Czechoslovakia. I was of course opposed to this measure, but I still thought, as did my colleagues at the psychiatric university hospital in Prague where I was working, that homosexuality was an experientially acquired neurosis". He then developed phallometry to replace psychoanalytic methods of assessment because "[P]sychoanalysis had turned out to be a failure, virtually unusable as an instrument for individual diagnosis or research....When phallometry began to look promising as a test of erotic sex and age preferences, we started using it mainly as a test of pedophilia, that is determining who has an erotic preference for children over adults". In post-World War II Czechoslovakia, Freund was assigned by the communist government the task of identifying among military conscripts men who were falsely declaring themselves to be gay to avoid the draft. "Freund (1957) developed the first device, which measured penile volume changes... to distinguish heterosexual and homosexual males for the Czechoslovak army." When he escaped Europe for Canada, Freund was able to pursue his research using phallometry for the assessment of sexual offenders. At that time, attempts to develop methods of changing homosexual men into heterosexual men were being made by many sexologists, including John Bancroft, Albert Ellis, and William Masters of the Masters and Johnson Institute. Because phallometry showed that such methods were failures, Freund was among the first sexologists to declare that such attempts were unethical. Based primarily on Freund's studies, decriminalization of homosexuality took place in Czechoslovakia in 1961. (See also LGBT rights in the Czech Republic.)

… excerpt ends here. Continue reading the full article.

Illustrations

Penile plethysmography illustration

Worked examples

Example 1 — a first encounter with Penile plethysmography

Start with the simplest possible case. Write down what Penile plethysmography claims or describes in one sentence, then invent the smallest concrete situation in which that sentence is true. In science, the smallest case is usually a single object, a single equation or a single measurement. Check that every symbol or term in your sentence has a meaning in that case.

Example 2 — changing one variable

Take the situation from Example 1 and change exactly one quantity: double it, halve it, or set it to zero. Predict what should happen to Penile plethysmography before you calculate. Comparing your prediction with the result is the fastest way to find out whether you understand the idea or only the words.

Example 3 — an exam-style question

Typical questions about Penile plethysmography ask you to (a) state it precisely, (b) apply it to given data, and (c) explain a limitation. Practise writing all three answers in under five minutes; the third part is what separates a full-mark answer from an average one.

Applications of Penile plethysmography

In research
Penile plethysmography appears in science research whenever the underlying quantities have to be modelled precisely. Papers usually cite it as a starting assumption and then explore where it breaks down.
In technology and industry
Engineering practice reuses Penile plethysmography in design rules, simulations and safety margins. Knowing the idea lets you read a specification sheet and understand why the numbers look the way they do.
In the classroom
Penile plethysmography is common in secondary-school and first-year university syllabi. It links to neighbouring topics Flow meters, Human penis, Male genital procedures, so understanding it makes those chapters shorter.
In everyday life
Look for Penile plethysmography outside the textbook — in sport, cooking, traffic, electronics or the sky above you. An example you found yourself is remembered far longer than one you were given.
Ask Teacher Smith questions about this articleOpens your AI tutor with a question about “Penile plethysmography” →

Affiliate

Preply — study more efficiently by working with a personal tutor. 50% off.

How to study Penile plethysmography in 20 minutes

  1. Read the reference excerpt below once, without taking notes.
  2. Close the page and write down what Penile plethysmography means in your own words.
  3. Compare your version with the excerpt and mark what you missed.
  4. Work through the three examples above with pen and paper.
  5. Explain Penile plethysmography out loud to somebody else — or to Teacher Smith in the lgStudy chat.

Frequently asked questions

What is Penile plethysmography in simple terms?

Penile plethysmography (PPG) or phallometry is a measurement of blood flow to the penis, typically used as a proxy for measurement of sexual arousal. The most commonly reported methods of conducting penile plethysmography involves the measurement of the circumference of the penis with a mercury-in…

Why does Penile plethysmography matter?

Because it connects several science ideas at once: it gives you a definition you can apply, a quantity you can calculate, and a way to check whether a result is plausible.

How should I study Penile plethysmography?

Read the excerpt, restate it from memory, then work through the examples and applications listed on this page. The five-step study plan above takes about twenty minutes.

What does this page cover?

It gives you a compact reference excerpt plus original lgStudy explanations, examples, applications and study material on Penile plethysmography.

Tags

  • Flow meters
  • Human penis
  • Male genital procedures
  • Medical testing equipment
  • Sexology
  • Sexual sadism disorder

Keep exploring