In power engineering, a power-flow study is a numerical analysis of the flow of electric power in an interconnected system. It is also known as power-flow analysis, load-flow study or load-flow analysis, with or without the hyphen. It analyzes the power systems in normal steady-state operation and may analyze the system’s capability to adequately supply the connected load. The principal information obtained from the power-flow study is the magnitude and phase angle of the voltage at each bus, and the real power and reactive power flowing in each line. The total system losses and individual line losses are also tabulated. A power-flow study usually uses simplified notations such as a one-line diagram and per-unit system. In terms of its approach to uncertainties, power-flow study can be divided to deterministic power-flow study and uncertainty-concerned power-flow study. Deterministic power-flow study does not take into account the uncertainties arising from both power generations and load behaviors. To take the uncertainties into consideration, there are several approaches that has been used such as probabilistic, possibilistic, information gap decision theory, robust optimization, and interval analysis. Performing a power-flow study on an existing system provides insight and recommendations as to the system operation and optimization of control settings to obtain maximum capacity while minimizing the operating costs. Power-flow studies are important for planning future expansion of power systems as well as in determining the best operation of existing systems, especially for the optimal operations of groups of generating units. A power-flow study is especially valuable for a system with multiple load centers, such as a refinery complex. Commercial power systems are usually too complex to allow for hand solution of the power flow. Special-purpose network analyzers were built between 1929 and the early 1960s to provide laboratory-scale physical models of power systems. Large-scale digital computers replaced the analog methods with numerical solutions. In addition to a power-flow study, computer programs perform related calculations such as short-circuit fault analysis, stability studies (transient and steady-state), unit commitment and economic dispatch. In particular, some programs use linear programming to find the optimal power flow, the conditions which give the lowest cost per kilowatt hour delivered.
Model An alternating current power-flow model is a model used in electrical engineering to analyze power grids. It provides a nonlinear system of equations which describes the energy flow through each transmission line. The problem is non-linear because the power flow into load impedances is a function of the square of the applied voltages. Due to nonlinearity, in many cases the analysis of large network via AC power-flow model is not feasible, and a linear (but less accurate) DC power-flow model is used instead. Usually, analysis of a three-phase power system is simplified by assuming balanced loading of all three phases. Sinusoidal steady-state operation is assumed, with no transient changes in power flow or voltage due to load or generation changes, meaning all current and voltage waveforms are sinusoidal with no DC offset and have the same constant frequency. The previous assumption is the same as assuming the power system is linear time-invariant (even though the system of equations is nonlinear), driven by sinusoidal sources of same frequency, and operating in steady-state, which allows to use phasor analysis, another simplification. A further simplification is to use the per-unit system to represent all voltages, power flows, and impedances, scaling the actual target system values to some convenient base. A system one-line diagram is the basis to build a mathematical model of the generators, loads, buses, and transmission lines of the system, and their electrical impedances and ratings. DC power flow (also known as DC load flow, or DCLF) gives estimations of lines power flows on AC power systems. Despite the name, DC power flow is not an analysis on direct current, but rather on alternating current; the name comes from the linearity of the analysis, which resembles analysis on direct current. DC power flow looks only at active power flows and neglects reactive power flows. This method is non-iterative and absolutely convergent but less accurate than AC Load Flow solutions. DC power flow is used wherever repetitive and fast load flow estimations are required.
… excerpt ends here. Continue reading the full article.