ArticleslgStudy

engineering

Pre-charge

Pre-charge is a engineering topic covered in the lgStudy science library. This page brings together a partial reference excerpt, illustrations, worked examples, real-world applications and a short study plan, so you can understand Pre-charge rather than just read about it. In short: Pre-charge of the powerline voltages in a high voltage DC application is a preliminary mode which limits the inrush current during the power up procedure. A high-voltage system with a large capacitive load can be exposed to high electric current during initial turn-on.

Pre-charge — main illustration
Pre-charge — illustration

Key takeaways

  • Pre-charge belongs to engineering; place it in that map before memorising details.
  • Learn the definition first, then one example that makes the definition concrete.
  • Connect Pre-charge to a quantity you can measure, compute or draw — that is where exam questions come from.
  • Reproduce the core statement of Pre-charge from memory before moving on to harder problems.

Reference excerpt

Pre-charge of the powerline voltages in a high voltage DC application is a preliminary mode which limits the inrush current during the power up procedure. A high-voltage system with a large capacitive load can be exposed to high electric current during initial turn-on. This current, if not limited, can cause considerable stress or damage to the system components. In some applications, the occasion to activate the system is a rare occurrence, such as in commercial utility power distribution. In other systems such as vehicle applications, pre-charge will occur with each use of the system, multiple times per day. Precharging is implemented to increase the lifespan of electronic components and increase reliability of the high voltage system.

Background: inrush currents into capacitors Inrush currents into capacitive components are a key concern in power-up stress to components. When DC input power is applied to a capacitive load, the step response of the voltage input will cause the input capacitor to charge. The capacitor charging starts with an inrush current and ends with an exponential decay down to the steady state condition. When the magnitude of the inrush peak is very large compared to the maximum rating of the components, then component stress is to be expected. The current into a capacitor is known to be I = C ( d V / d T ) {\displaystyle I=C(dV/dT)} : the peak inrush current will depend upon the capacitance C and the rate of change of the voltage (dV/dT). The inrush current will increase as the capacitance value increases, and the inrush current will increase as the voltage of the power source increases. This second parameter is of primary concern in high voltage power distribution systems. By their nature, high voltage power sources will deliver high voltage into the distribution system. Capacitive loads will then be subject to high inrush currents upon power-up. The stress to the components must be understood and minimized. The objective of a pre-charge function is to limit the magnitude of the inrush current into capacitive loads during power-up. This may take several seconds depending on the system. In general, higher voltage systems benefit from longer pre-charge times during power-up.

Consider an example where a high voltage source powers up a typical electronics control unit which has an internal power supply with 11000 μF input capacitance. When powered from a 28 V source, the inrush current into the electronics unit would approach 31 amperes in 10 milliseconds. If that same circuit is activated by a 610 V source, then the inrush current would approach 670 A in 10 milliseconds. It is wise not to allow unlimited inrush currents from high voltage power distribution system activation into capacitive loads: instead the inrush current should be controlled to avoid power-up stress to components.

Definition of a pre-charge function

The functional requirement of the high voltage pre-charge circuit is to minimize the peak current out from the power source by slowing down the dV/dT of the input power voltage such that a new "pre-charge mode" is created. The inductive loads on the distribution system must be switched off during the pre-charge mode, due to the dI/dT dependency. While pre-charging, the system voltage will rise slowly and controllably with power-up current never exceeding the maximum allowed value. As the circuit voltage approaches near steady state, then the pre-charge function is complete. Normal operation of a pre-charge circuit is to terminate pre-charge mode when the circuit voltage is 90% or 95% of the operating voltage. Upon completion of pre-charging, the pre-charge resistance is switched out of the power supply circuit and returns to a low impedance power source for normal mode. The high voltage loads are then powered up sequentially. The simplest inrush-current limiting system, used in many consumer electronics devices, is a NTC resistor. When cold, its high resistance allows a small current to pre-charge the reservoir capacitor. After it warms up, its low resistance more efficiently passes the working current. Many active power factor correction systems also include soft start. If the example circuit from before is used with a pre-charge circuit which limits the dV/dT to less than 600 volts per second, then the inrush current will be reduced from 670 amperes to 7 amperes. This is a "kinder and gentler" way to activate a high voltage DC power distribution system.

… excerpt ends here. Continue reading the full article.

Illustrations

Pre-charge: Peak inrush current into a high voltage capacitor upon power up can stress the component, reducing its reliability.
Peak inrush current into a high voltage capacitor upon power up can stress the component, reducing its reliability.
Pre-charge: Precharging a high voltage DC power distribution line can control the inrush current into capacitive components, reducing stress and supporting a long component life.
Precharging a high voltage DC power distribution line can control the inrush current into capacitive components, reducing stress and supporting a long component life.

Worked examples

Example 1 — a first encounter with Pre-charge

Start with the simplest possible case. Write down what Pre-charge claims or describes in one sentence, then invent the smallest concrete situation in which that sentence is true. In engineering, the smallest case is usually a single object, a single equation or a single measurement. Check that every symbol or term in your sentence has a meaning in that case.

Example 2 — changing one variable

Take the situation from Example 1 and change exactly one quantity: double it, halve it, or set it to zero. Predict what should happen to Pre-charge before you calculate. Comparing your prediction with the result is the fastest way to find out whether you understand the idea or only the words.

Example 3 — an exam-style question

Typical questions about Pre-charge ask you to (a) state it precisely, (b) apply it to given data, and (c) explain a limitation. Practise writing all three answers in under five minutes; the third part is what separates a full-mark answer from an average one.

Applications of Pre-charge

In research
Pre-charge appears in engineering research whenever the underlying quantities have to be modelled precisely. Papers usually cite it as a starting assumption and then explore where it breaks down.
In technology and industry
Engineering practice reuses Pre-charge in design rules, simulations and safety margins. Knowing the idea lets you read a specification sheet and understand why the numbers look the way they do.
In the classroom
Pre-charge is common in secondary-school and first-year university syllabi. It links to neighbouring topics Electric power transmission systems, Electrical engineering, Electrical power control, so understanding it makes those chapters shorter.
In everyday life
Look for Pre-charge outside the textbook — in sport, cooking, traffic, electronics or the sky above you. An example you found yourself is remembered far longer than one you were given.

Affiliate

Preply — study more efficiently by working with a personal tutor. 50% off.

How to study Pre-charge in 20 minutes

  1. Read the reference excerpt below once, without taking notes.
  2. Close the page and write down what Pre-charge means in your own words.
  3. Compare your version with the excerpt and mark what you missed.
  4. Work through the three examples above with pen and paper.
  5. Explain Pre-charge out loud to somebody else — or to Teacher Smith in the lgStudy chat.

Frequently asked questions

What is Pre-charge in simple terms?

Pre-charge of the powerline voltages in a high voltage DC application is a preliminary mode which limits the inrush current during the power up procedure. A high-voltage system with a large capacitive load can be exposed to high electric current during initial turn-on.

Why does Pre-charge matter?

Because it connects several engineering ideas at once: it gives you a definition you can apply, a quantity you can calculate, and a way to check whether a result is plausible.

How should I study Pre-charge?

Read the excerpt, restate it from memory, then work through the examples and applications listed on this page. The five-step study plan above takes about twenty minutes.

What does this page cover?

It gives you a compact reference excerpt plus original lgStudy explanations, examples, applications and study material on Pre-charge.

Tags

  • Electric power transmission systems
  • Electrical engineering
  • Electrical power control
  • Electronic engineering

Keep exploring