Probe electrospray ionization

Probe electrospray ionization is a science topic covered in the lgStudy science library. This page brings together a partial reference excerpt, illustrations, worked examples, real-world applications and a short study plan, so you can understand Probe electrospray ionization rather than just read about it. In short: Probe electrospray ionization (PESI) is an electrospray-based ambient ionization technique which is coupled with mass spectrometry for sample analysis. Unlike traditional mass spectrometry ion sources which must be maintained in a vacuum, ambient ionization techniques permit sample ionization under ambient conditions, allowing for the high-throughput analysis of samples in their native state, often with minimal or n…

Probe electrospray ionization — main illustration
Probe electrospray ionization — illustration

Key takeaways

  • Probe electrospray ionization belongs to science; place it in that map before memorising details.
  • Learn the definition first, then one example that makes the definition concrete.
  • Connect Probe electrospray ionization to a quantity you can measure, compute or draw — that is where exam questions come from.
  • Reproduce the core statement of Probe electrospray ionization from memory before moving on to harder problems.

Reference excerpt

Probe electrospray ionization (PESI) is an electrospray-based ambient ionization technique which is coupled with mass spectrometry for sample analysis. Unlike traditional mass spectrometry ion sources which must be maintained in a vacuum, ambient ionization techniques permit sample ionization under ambient conditions, allowing for the high-throughput analysis of samples in their native state, often with minimal or no sample pre-treatment. The PESI ion source simply consists of a needle to which a high voltage is applied following sample pick-up, initiating electrospray directly from the solid needle.

History Probe electrospray ionization is an ambient ionization mass spectrometry technique developed by Kenzo Hiraoka et al. at the University of Yamanashi, Japan. The technique was developed to address some of the issues associated with traditional electrospray ionization (ESI), including clogging of the capillary and contamination, whilst providing a means of rapid and direct sample analysis. Since its initial conception, various modified forms of the PESI ion source have been developed, and the PESI-MS system has been commercialized by instrument manufacturing company Shimadzu.

Principle of operation The PESI ion source consists of a solid needle or wire which acts as both the sampling probe and electrospray emitter. The needle is moved up and down along a vertical axis, a process which can be either automated or manual. When the needle is lowered to the sampling stage, the tip of the needle briefly touches the surface of a typical liquid sample. During this stage, the needle is held at ground potential. The needle is then raised to be level with the mass spectrometer inlet where a high voltage of 2–3 kV is applied. Electrospray is induced at the tip of the needle, producing analyte ions which are drawn into the mass spectrometer for analysis. The mechanism by which ions are formed is believed to be identical to traditional electrospray ionization. As a result, in positive ion mode analytes are often observed as the protonated, sodiated and potentiated ions, depending on the sample and analyte type.

Although the amount of sample picked up by the needle is largely dependent on sample viscosity, it has been estimated that just a few picolitres of the sample solution are typically used. Because of this, the technique can be applied to small sample sizes, particularly ideal when limited sample amounts are available. As such a small sample amount is picked up and completely exhausted during the ionization process, issues of contamination are severely reduced. Furthermore, the process of sampling and ionization takes just a few seconds, so PESI-MS is suitable for high-throughput analysis.

Sequential ionization A phenomenon observed with probe electrospray ionization is the sequential and exhaustive ionization of analytes with different surface activities. During the development of PESI, it was discovered that analytes could be sequentially ionized throughout the electrospray, thus enabling a temporal separation of components within a sample. In normal ESI, the sample solution is typically continuously supplied through a capillary and the charged droplets contain all sample components, with more surface-active analytes being constantly preferentially ionized. In PESI, surface-active analytes are also preferentially ionized. However, as a finite droplet exists on the tip of the needle, following the depletion of surface-active analytes, the remaining components in the droplet can then be ionized and observed. This can result in the production of distinctively different mass spectra from a single sample over the application of the high voltage for just a few seconds. This effect offers a particular advantage in the analysis of analytes suffering from ion suppression effects. The presence of surface-active analytes or charged solvent additives can result in the suppressed ionization of analytes of interest, resulting in low sensitivity or the complete absence of the analyte. The effects of ion suppression can be minimized by reducing the complexity of the sample, for instance through sample extraction techniques such as solid phase extraction, or by separation of analytes of interest using chromatographic separation. However, these sample preparation steps can be laborious, time-consuming and expensive. PESI enables a reduction in ion suppression without the need for sample pre-treatment. By separating the ionization of different analytes, components causing ion suppression can be exhausted before enabling the ionization of components of interest. This has been demonstrated in a number of scenarios, including in the analysis of raw urine, with concentrated components such as creatinine ionization initially, followed by the appearance of previously undetected metabolites.

Sheath-flow PESI As the PESI needle is only applicable to liquid or penetrable solid samples, it cannot be used for the analysis of the majority of dry solid materials. To circumvent this limitation, sheath-flow probe electrospray ionization (sfPESI) was developed, a modification of the traditional PESI technique. The sfPESI ion source consists of a solid needle housed within a plastic sheath (typically a gel-loading tip) filled with a small amount of solvent. The needle protrudes from the base of the sheath by approximately 0.1 mm, where a minute solvent droplet is held. The based of based the probe is briefly touched to the sample surface, where a convex solvent meniscus forms between the probe and the sample, wetting the sample and enabling analyte extraction. The chemistry of the solvent can be modified to induce the extraction of particular analytes of interest. After application to the sample, the sfPESI probe is then raised to be level with the mass spectrometer inlet, with solubilised analytes held in the droplet at the tip of the needle, and a high voltage applied. sfPESI offers the same advantages as standard PESI, including the sequential and exhaustive ionization phenomenon, whilst enabling the direct analysis of dry samples.

… excerpt ends here. Continue reading the full article.

Worked examples

Example 1 — a first encounter with Probe electrospray ionization

Start with the simplest possible case. Write down what Probe electrospray ionization claims or describes in one sentence, then invent the smallest concrete situation in which that sentence is true. In science, the smallest case is usually a single object, a single equation or a single measurement. Check that every symbol or term in your sentence has a meaning in that case.

Example 2 — changing one variable

Take the situation from Example 1 and change exactly one quantity: double it, halve it, or set it to zero. Predict what should happen to Probe electrospray ionization before you calculate. Comparing your prediction with the result is the fastest way to find out whether you understand the idea or only the words.

Example 3 — an exam-style question

Typical questions about Probe electrospray ionization ask you to (a) state it precisely, (b) apply it to given data, and (c) explain a limitation. Practise writing all three answers in under five minutes; the third part is what separates a full-mark answer from an average one.

Applications of Probe electrospray ionization

In research
Probe electrospray ionization appears in science research whenever the underlying quantities have to be modelled precisely. Papers usually cite it as a starting assumption and then explore where it breaks down.
In technology and industry
Engineering practice reuses Probe electrospray ionization in design rules, simulations and safety margins. Knowing the idea lets you read a specification sheet and understand why the numbers look the way they do.
In the classroom
Probe electrospray ionization is common in secondary-school and first-year university syllabi. It links to neighbouring topics Ionization, so understanding it makes those chapters shorter.
In everyday life
Look for Probe electrospray ionization outside the textbook — in sport, cooking, traffic, electronics or the sky above you. An example you found yourself is remembered far longer than one you were given.

Affiliate

Preply — study more efficiently by working with a personal tutor. 50% off.

How to study Probe electrospray ionization in 20 minutes

  1. Read the reference excerpt below once, without taking notes.
  2. Close the page and write down what Probe electrospray ionization means in your own words.
  3. Compare your version with the excerpt and mark what you missed.
  4. Work through the three examples above with pen and paper.
  5. Explain Probe electrospray ionization out loud to somebody else — or to Teacher Smith in the lgStudy chat.

Frequently asked questions

What is Probe electrospray ionization in simple terms?

Probe electrospray ionization (PESI) is an electrospray-based ambient ionization technique which is coupled with mass spectrometry for sample analysis. Unlike traditional mass spectrometry ion sources which must be maintained in a vacuum, ambient ionization techniques permit sample ionization under…

Why does Probe electrospray ionization matter?

Because it connects several science ideas at once: it gives you a definition you can apply, a quantity you can calculate, and a way to check whether a result is plausible.

How should I study Probe electrospray ionization?

Read the excerpt, restate it from memory, then work through the examples and applications listed on this page. The five-step study plan above takes about twenty minutes.

What does this page cover?

It gives you a compact reference excerpt plus original lgStudy explanations, examples, applications and study material on Probe electrospray ionization.