ArticleslgStudy

chemistry

Scanning electrochemical microscopy

Scanning electrochemical microscopy is a chemistry topic covered in the lgStudy science library. This page brings together a partial reference excerpt, illustrations, worked examples, real-world applications and a short study plan, so you can understand Scanning electrochemical microscopy rather than just read about it. In short: Scanning electrochemical microscopy (SECM) is a technique within the broader class of scanning probe microscopy (SPM) that is used to measure the local electrochemical behavior of liquid/solid, liquid/gas and liquid/liquid interfaces. Initial characterization of the technique was credited to University of Texas electrochemist, Allen J.

Scanning electrochemical microscopy — main illustration
Scanning electrochemical microscopy — illustration

Key takeaways

  • Scanning electrochemical microscopy belongs to chemistry; place it in that map before memorising details.
  • Learn the definition first, then one example that makes the definition concrete.
  • Connect Scanning electrochemical microscopy to a quantity you can measure, compute or draw — that is where exam questions come from.
  • Reproduce the core statement of Scanning electrochemical microscopy from memory before moving on to harder problems.

Reference excerpt

Scanning electrochemical microscopy (SECM) is a technique within the broader class of scanning probe microscopy (SPM) that is used to measure the local electrochemical behavior of liquid/solid, liquid/gas and liquid/liquid interfaces. Initial characterization of the technique was credited to University of Texas electrochemist, Allen J. Bard, in 1989. Since then, the theoretical underpinnings have matured to allow widespread use of the technique in chemistry, biology and materials science. Spatially resolved electrochemical signals can be acquired by measuring the current at an ultramicroelectrode (UME) tip as a function of precise tip position over a substrate region of interest. Interpretation of the SECM signal is based on the concept of diffusion-limited current. Two-dimensional raster scan information can be compiled to generate images of surface reactivity and chemical kinetics. The technique is complementary to other surface characterization methods such as surface plasmon resonance (SPR), electrochemical scanning tunneling microscopy (ESTM), and atomic force microscopy (AFM) in the interrogation of various interfacial phenomena. In addition to yielding topographic information, SECM is often used to probe the surface reactivity of solid-state materials, electrocatalyst materials, enzymes and other biophysical systems. SECM and variations of the technique have also found use in microfabrication, surface patterning, and microstructuring.

History The emergence of ultramicroelectrodes (UMEs) around 1980 was pivotal to the development of sensitive electroanalytical techniques like SECM. UMEs employed as probes enabled the study of quick or localized electrochemical reactions. The first SECM-like experiment was performed in 1986 by Engstrom to yield direct observation of reaction profiles and short-lived intermediates. Simultaneous experiments by Allen J. Bard using an Electrochemical Scanning Tunneling Microscope (ESTM) demonstrated current at large tip-to-sample distances that was inconsistent with electron tunneling. This phenomenon was attributed to Faradaic current, compelling a more thorough analysis of electrochemical microscopy. The theoretical basis was presented in 1989 by Bard, where he also coined the term Scanning Electrochemical Microscopy. In addition to the simple collection modes used at the time, Bard illustrated the widespread utility of SECM through the implementation of various feedback modes. As the theoretical foundation developed, annual SECM-related publications steadily rose from 10 to around 80 in 1999, when the first commercial SECM became available. SECM continues to increase in popularity due to theoretical and technological advances that expand experimental modes while broadening substrate scope and enhancing sensitivity.

Principles of operation Electric potential is manipulated through the UME tip in a bulk solution containing a redox-active couple (e.g. Fe2+/Fe3+). When a sufficiently negative potential is applied, (Fe3+) is reduced to (Fe2+) at the UME tip, generating a diffusion-limited current. The steady-state current is governed by the flux of oxidized species in solution to the UME disc and is given by:

i T , ∞ = 4 n F C D a {\displaystyle i_{T,\infty }=4nFCDa}

where iT,∞ is the diffusion-limited current, n is the number of electrons transferred at the electrode tip (O + ne− → R), F is Faraday's constant, C is the concentration of the oxidized species in solution, D is the diffusion coefficient and a is the radius of the UME disc. In order to probe a surface of interest, the tip is moved closer to the surface and changes in current are measured. There are two predominant modes of operation, which are feedback mode and collection-generation mode.

Feedback mode

In a bulk solution, the oxidized species is reduced at the tip, producing a steady-state current that is limited by hemispherical diffusion. As the tip approaches a conductive substrate in the solution, the reduced species formed at the tip is oxidized at the conductive surface, yielding an increase in the tip current and creating a regenerative "positive" feedback loop. The opposite effect is observed when probing insulating surfaces, as the oxidized species cannot be regenerated and diffusion to the electrode is inhibited as a result of physical obstruction as the tip approaches the substrate, creating a "negative" feedback loop and decreasing the tip current. An additional parameter to consider when probing insulating surfaces is the electrode sheath diameter, rg, since it contributes to the physical obstruction of diffusion. The change in tip current as a function of distance d can be plotted as an "approach curve" as shown. Due to the rate dependent nature of SECM measurements, it is also employed to study electron-transfer kinetics.

Collection-generation modes Another mode of operation that is employed is tip generation/substrate collection (TG/SC). In TG/SC mode, the tip is held at a potential sufficient for an electrode reaction to occur and "generate" a product while the substrate is held at a potential sufficient for the electrode product to react with or be "collected" by the substrate. The reciprocal to this method is substrate generation/tip collection (SG/TC), where the substrate acts to generate a species that is measured at the tip. Both TG/SC and SG/TC variations are also categorized as "direct" modes. Two currents are generated: the tip current, iT, and the substrate current, iS. Since the substrate is generally much larger than the tip, the efficiency of collection, iS/iT, is 1 if no reactions occur during the transfer of tip-generated species to the substrate. As the distance between tip and substrate, d, decreases, the collection efficiency, iS/iT, approaches 1.

… excerpt ends here. Continue reading the full article.

Illustrations

Scanning electrochemical microscopy: SECM Electrode scanning in constant-height mode
SECM Electrode scanning in constant-height mode
Scanning electrochemical microscopy: Schematic of the fundamental devices involved in most SECM experiments. Experimental control is exercised through manipulation of the piezo controller and potential programmer, while data is collected through the bipotentiostat.
Schematic of the fundamental devices involved in most SECM experiments. Experimental control is exercised through manipulation of the piezo controller and potential programmer, while data is collected through the bipotentiostat.
Scanning electrochemical microscopy: (A) Schematics of an ultramicroelectrode. The exposed metal is the active part of the electrode. (B) Optical micrograph of a tip. The platinum wire (orange) is sealed inside a glass sheath.
(A) Schematics of an ultramicroelectrode. The exposed metal is the active part of the electrode. (B) Optical micrograph of a tip. The platinum wire (orange) is sealed inside a glass sheath.
Scanning electrochemical microscopy: Ionic dissolution of crystal by local reduction of Mn+
Ionic dissolution of crystal by local reduction of Mn+
Scanning electrochemical microscopy: Substrate imaging (constant current mode). (A) SECM image of a portion (10 μm × 10 μm) of a human breast cell using a 120 nm radius tip. (B) Optical micrograph of the same cell showing the SECM image area delimited by a white square. SECM
Substrate imaging (constant current mode). (A) SECM image of a portion (10 μm × 10 μm) of a human breast cell using a 120 nm radius tip. (B) Optical micrograph of the same cell showing the SECM image area delimited by a white square. SECM

Worked examples

Example 1 — a first encounter with Scanning electrochemical microscopy

Start with the simplest possible case. Write down what Scanning electrochemical microscopy claims or describes in one sentence, then invent the smallest concrete situation in which that sentence is true. In chemistry, the smallest case is usually a single object, a single equation or a single measurement. Check that every symbol or term in your sentence has a meaning in that case.

Example 2 — changing one variable

Take the situation from Example 1 and change exactly one quantity: double it, halve it, or set it to zero. Predict what should happen to Scanning electrochemical microscopy before you calculate. Comparing your prediction with the result is the fastest way to find out whether you understand the idea or only the words.

Example 3 — an exam-style question

Typical questions about Scanning electrochemical microscopy ask you to (a) state it precisely, (b) apply it to given data, and (c) explain a limitation. Practise writing all three answers in under five minutes; the third part is what separates a full-mark answer from an average one.

Applications of Scanning electrochemical microscopy

In research
Scanning electrochemical microscopy appears in chemistry research whenever the underlying quantities have to be modelled precisely. Papers usually cite it as a starting assumption and then explore where it breaks down.
In technology and industry
Engineering practice reuses Scanning electrochemical microscopy in design rules, simulations and safety margins. Knowing the idea lets you read a specification sheet and understand why the numbers look the way they do.
In the classroom
Scanning electrochemical microscopy is common in secondary-school and first-year university syllabi. It links to neighbouring topics Microscopy, so understanding it makes those chapters shorter.
In everyday life
Look for Scanning electrochemical microscopy outside the textbook — in sport, cooking, traffic, electronics or the sky above you. An example you found yourself is remembered far longer than one you were given.
Ask Teacher Smith questions about this articleOpens your AI tutor with a question about “Scanning electrochemical microscopy” →

Affiliate

Preply — study more efficiently by working with a personal tutor. 50% off.

How to study Scanning electrochemical microscopy in 20 minutes

  1. Read the reference excerpt below once, without taking notes.
  2. Close the page and write down what Scanning electrochemical microscopy means in your own words.
  3. Compare your version with the excerpt and mark what you missed.
  4. Work through the three examples above with pen and paper.
  5. Explain Scanning electrochemical microscopy out loud to somebody else — or to Teacher Smith in the lgStudy chat.

Frequently asked questions

What is Scanning electrochemical microscopy in simple terms?

Scanning electrochemical microscopy (SECM) is a technique within the broader class of scanning probe microscopy (SPM) that is used to measure the local electrochemical behavior of liquid/solid, liquid/gas and liquid/liquid interfaces. Initial characterization of the technique was credited to Univer…

Why does Scanning electrochemical microscopy matter?

Because it connects several chemistry ideas at once: it gives you a definition you can apply, a quantity you can calculate, and a way to check whether a result is plausible.

How should I study Scanning electrochemical microscopy?

Read the excerpt, restate it from memory, then work through the examples and applications listed on this page. The five-step study plan above takes about twenty minutes.

What does this page cover?

It gives you a compact reference excerpt plus original lgStudy explanations, examples, applications and study material on Scanning electrochemical microscopy.

Tags

  • Microscopy

Keep exploring