Schirmer's test is a science topic covered in the lgStudy science library. This page brings together a partial reference excerpt, illustrations, worked examples, real-world applications and a short study plan, so you can understand Schirmer's test rather than just read about it. In short: Schirmer's test determines whether the eye produces enough tears to keep it moist. This test is used when a person experiences very dry eyes or excessive watering of the eyes.

Schirmer's test — main illustration
Schirmer's test — illustration

Key takeaways

  • Schirmer's test belongs to science; place it in that map before memorising details.
  • Learn the definition first, then one example that makes the definition concrete.
  • Connect Schirmer's test to a quantity you can measure, compute or draw — that is where exam questions come from.
  • Reproduce the core statement of Schirmer's test from memory before moving on to harder problems.

Reference excerpt

Schirmer's test determines whether the eye produces enough tears to keep it moist. This test is used when a person experiences very dry eyes or excessive watering of the eyes. It can cause damage to the cornea. A negative (more than 10 mm of moisture on the Schirmer strip in 5 minutes) test result is normal. Both eyes normally secrete the same amount of tears.

History The test is named after Otto Schirmer. Historically, the strips have been manufactured from various materials, including blotting paper, litmus paper, and cigarette paper. Whatman standard No. 41 filter paper and Black Ribbon No. 589 were later recommended as standardized materials. Manufacturers generally do not specify the exact origins of the materials they use, even though these papers are still commonly employed. As a result, Schirmer strips available on the market can differ visibly, even under simple inspection. Such inconsistencies may alter test performance and potentially influence clinical interpretation.

Test procedure

The test works by the principle of capillary action, which allows the water in tears to travel along the length of a paper test strip in an identical fashion as a horizontal capillary tube. The rate of travel along the test strip is proportional to the rate of tear production. The patient is instructed to look upward, and the patient's eyelid is pulled down. The bent end of the test strip is placed in the eye such that it rests between the palpebral conjunctiva of the lower eyelid and the bulbar conjunctiva of the eye. Schirmer's test uses paper strips inserted into the eye for several minutes to measure the production of tears. Both eyes are tested at the same time. Most often, this test consists of placing a small strip of filter paper inside the lower eyelid (inferior fornix). The eyes are closed for approximately 5 minutes. The paper is then removed and the amount of moisture is measured. After five minutes, the patient is asked to open both eyes and look upward so the test strips may be removed. The Schirmer test score is determined by the length of the moistened area of the strips (using the scale packaged with the strips) The use of the anesthetic ensures that only basal tear secretion is being measured. A young person normally moistens 15 mm of each paper strip. Because hypolacrimation occurs with aging, 33% of normal elderly persons may wet only 10 mm in 5 minutes. Persons with Sjögren's disease moisten less than 5 mm in 5 minutes. How to read results of the Schirmer's test:

1. Normal which is ≥10 mm wetting of the paper after 5 minutes. 2. Tear deficiency which is <5 mm wetting of the paper after 5 minutes. Notably, the closed-eye method is generally preferred over open-eye testing, as it accounts for variables such as humidity, temperature, tear evaporation, brightness, and tear-stimulating effects from the lid margin and eyelashes. Maintaining the eyes softly closed, rather than tightly shut, further reduces discomfort. Gaze position has also been shown to affect Schirmer test results, with higher values recorded when the test is performed with an inferior gaze. Additionally, diurnal variations can influence visual function and ocular surface physiology in individuals with dry eye.

Benefits and limitations The Schirmer test is one of the three primary diagnostic assessments recommended by the Tear Film and Ocular Surface Society's Dry Eye Workshop II (TFOS DEWS II) report. Cut-off values for diagnosing dry eye are variable, ranging from ≤10 mm over 5 minutes (TFOS DEWS II) to 5–15 mm, depending on disease severity and testing methodology. The test has been shown to be a robust predictor of dry eye disease severity, irrespective of the cut-off level used (5, 10, or 15 mm). This test is straightforward, accessible, low-cost, and broadly adopted. However, it has several limitations, including low reproducibility, limited sensitivity and specificity, a relatively long testing time (~5 minutes), the risk of evaporative loss, high variability, patient discomfort, uneven tear absorption by the strip, and no clearly defined cut-off value. Despite these drawbacks, the Schirmer test is accepted as an effective tool for assessing dry eye, particularly in severe cases. In addition to their diagnostic use, Schirmer strips have been increasingly utilized for tear sampling, especially for analyzing proteins and metabolites. Some pre-analytical and analytical factors influencing tear metabolomics using Schirmer strips in dry eye disease have been addressed previously. Moreover, a workflow for tear proteome analysis has been established to facilitate biomarker discovery.

Alternatives With respect to its limitations, newer and improved tests of tear production and function are emerging.

One test measures an iron-binding molecule called lactoferrin. The amount of this molecule appears to be closely related to tear production. Patients with low tear production and dry eyes have low levels of this molecule. This test may be especially valuable for patients with dry eyes since it can point to specific treatment strategies for dry eye. The tears may also be examined for their content of lysozyme, an enzyme normally found in tears. Another test involves fluorescein eye drops, which contain a dye that is placed in the eye. The dye should drain with the tears through the lacrimal duct into the nose within 2 minutes. If patients do not have enough tears to flush the dye into the nose, this time will be longer. A new test is also available to more accurately measure the flow of dye out of the eye.

Eye dryness Dry eyes can occur from conditions such as:

Aging Arthritis Corneal ulcers and infections Diabetes Eye infections (for example conjunctivitis) Secondary tearing deficiency associated with disorders such as – lymphoma, leukemia, GVHD (graft vs. host disease, after a transplant) Sjögren's disease Triple A syndrome Vitamin A deficiency As a temporary or permanent side effect of LASER vision correction surgery such as LASIK or photorefractive keratectomy (PRK) The inability of tears to drain into the nose can occur with:

Some eye infections Blockage of the tear duct

See also Dry eye syndrome Tear break-up time

References

External links MedlinePlus Encyclopedia: Schirmer's test Photo Archived 2017-04-06 at the Wayback Machine Diagram

Illustrations

Schirmer's test illustration
Schirmer's test: Schirmer test = 0,00 in Sjögren's syndrome
Schirmer test = 0,00 in Sjögren's syndrome

Worked examples

Example 1 — a first encounter with Schirmer's test

Start with the simplest possible case. Write down what Schirmer's test claims or describes in one sentence, then invent the smallest concrete situation in which that sentence is true. In science, the smallest case is usually a single object, a single equation or a single measurement. Check that every symbol or term in your sentence has a meaning in that case.

Example 2 — changing one variable

Take the situation from Example 1 and change exactly one quantity: double it, halve it, or set it to zero. Predict what should happen to Schirmer's test before you calculate. Comparing your prediction with the result is the fastest way to find out whether you understand the idea or only the words.

Example 3 — an exam-style question

Typical questions about Schirmer's test ask you to (a) state it precisely, (b) apply it to given data, and (c) explain a limitation. Practise writing all three answers in under five minutes; the third part is what separates a full-mark answer from an average one.

Applications of Schirmer's test

In research
Schirmer's test appears in science research whenever the underlying quantities have to be modelled precisely. Papers usually cite it as a starting assumption and then explore where it breaks down.
In technology and industry
Engineering practice reuses Schirmer's test in design rules, simulations and safety margins. Knowing the idea lets you read a specification sheet and understand why the numbers look the way they do.
In the classroom
Schirmer's test is common in secondary-school and first-year university syllabi. It links to neighbouring topics Diagnostic ophthalmology, Veterinary diagnosis, so understanding it makes those chapters shorter.
In everyday life
Look for Schirmer's test outside the textbook — in sport, cooking, traffic, electronics or the sky above you. An example you found yourself is remembered far longer than one you were given.
Ask Teacher Smith questions about this articleOpens your AI tutor with a question about “Schirmer's test” →

Affiliate

Preply — study more efficiently by working with a personal tutor. 50% off.

How to study Schirmer's test in 20 minutes

  1. Read the reference excerpt below once, without taking notes.
  2. Close the page and write down what Schirmer's test means in your own words.
  3. Compare your version with the excerpt and mark what you missed.
  4. Work through the three examples above with pen and paper.
  5. Explain Schirmer's test out loud to somebody else — or to Teacher Smith in the lgStudy chat.

Frequently asked questions

What is Schirmer's test in simple terms?

Schirmer's test determines whether the eye produces enough tears to keep it moist. This test is used when a person experiences very dry eyes or excessive watering of the eyes.

Why does Schirmer's test matter?

Because it connects several science ideas at once: it gives you a definition you can apply, a quantity you can calculate, and a way to check whether a result is plausible.

How should I study Schirmer's test?

Read the excerpt, restate it from memory, then work through the examples and applications listed on this page. The five-step study plan above takes about twenty minutes.

What does this page cover?

It gives you a compact reference excerpt plus original lgStudy explanations, examples, applications and study material on Schirmer's test.