Voltage symmetrization system

Voltage symmetrization system is a engineering topic covered in the lgStudy science library. This page brings together a partial reference excerpt, illustrations, worked examples, real-world applications and a short study plan, so you can understand Voltage symmetrization system rather than just read about it. In short: Voltage Symmetrization System (VSS) was developed especially for electric power networks with great phase voltage unbalance. It is a three-phase system which enables earth-fault current and charging current elimination.

Voltage symmetrization system — main illustration
Voltage symmetrization system — illustration

Key takeaways

  • Voltage symmetrization system belongs to engineering; place it in that map before memorising details.
  • Learn the definition first, then one example that makes the definition concrete.
  • Connect Voltage symmetrization system to a quantity you can measure, compute or draw — that is where exam questions come from.
  • Reproduce the core statement of Voltage symmetrization system from memory before moving on to harder problems.

Reference excerpt

Voltage Symmetrization System (VSS) was developed especially for electric power networks with great phase voltage unbalance. It is a three-phase system which enables earth-fault current and charging current elimination. Until now, the operation with earth-fault current compensation has been very complicated for the networks with a great voltage unbalance. In the past, it was necessary to operate such networks with an isolated neutral, solid grounding or with a significantly untuned arc-suppression coil. VSS can also substitute for an arc-suppression coil or it can complement it parallelly. Moreover, it contributes to a better function of earth-fault protections for high-resistance earth faults by equalizing phase-to-earth capacity unbalance. The VSS was patented.

The three-phase VSS has several basic functions:

In a faultless condition: Symmetrization of phase voltage, i.e. elimination of phase voltage unbalance realized by controlling the phase-to-earth capacity unbalance in the network, Reduction of charging current value, i.e. elimination of charging current of phase-to-earth capacity which contributes to reduction of reactive capacity power flow in the network. During an earth fault: Elimination of earth-fault current (analogous to an arc-suppression coil, Controlling the residual active earth-fault current.

Faultless condition If VSS is used for phase voltage unbalance elimination only, it is possible to operate it with a relatively low power. The VSS can effectively eliminate and control the phase voltage unbalance, which is caused by phase-to-ground capacity unbalance. The system enables to automatically maintain phase-to-ground capacity unbalance of the network in the range of assigned parameters, and thus provides the network with symmetrical phase voltage in the assigned range as well. In particular cases, the VSS can be used for artificial increase in phase voltage unbalance of the network, mostly for a short-time period during earth-fault localization in the network.

Reduction of charging current value in a faultless condition If VSS is used for line's charging current elimination, it is not necessary to install shunt reactor. In single-phase cable lines, the VSS can eliminate the whole charging current because the operational capacity comprises phase-to-ground capacity only. In three-phase and overhead lines, the operational capacity comprises not only of phase-to-ground capacity but also of phase-to-phase capacity. VSS eliminates only charging currents of phase-to-ground capacity in these networks, which stands for 60% to 70% of line's operational capacity value (VSS is not designated for elimination of phase-to-phase capacity charging current in the lines). VSS contributes to a significant reduction of charging reactive power flow.

Elimination of earth-fault current during an earth fault The advantage of the system is that it does not require a neutral to eliminate the earth-fault current. Therefore, the VSS has been implemented especially in networks which were operated with isolated neutral. During an earth fault in the network, the system eliminates earth-fault current. The function is in principle similar to an arc-suppression coil. In comparison to the arc-suppression coil, VSS eliminates earth-fault current more efficiently, even in unbalanced or extremely unbalanced networks.

Controlling the residual active earth-fault current during an earth fault VSS enables to control the magnitude of residual active earth-fault current. This can be applied to improve the function of directional ground protection or to decrease great active earth-fault current in the network. Such quality is used in networks with great active earth-fault current value, for instance in large cable lines.

Note As VSS does not require neutral for its connection, it can be connected anywhere in the network. At the same time, it is possible to adjust its power to a certain part of the network only, which can be use in local distribution networks or in long feeders, in feeders with high value of charging current, or in feeders with high capacity unbalance. The part of the network in which VSS is installed does not increase the value of phase-to-earth capacity current in power supply network. Furthermore, the value of network's charging current decreases by the set system power. The VSS is very beneficial in networks with island operation. In island operation, the source is not loaded by charging current of the line and the separated island area is operated with resonant grounding. Such qualities cannot be reached with a classic arc-suppression coil.

Operational experience of VSS since 2005 VSS systems have been installed in industrial 6 kV networks as well as in standard distribution networks up to 35 kV. Operational experience proved that VSS can eliminate even extremely high cross parameters unbalance in the network without negatively influencing the function of earth fault protection. Thanks to elimination of phase capacity unbalance, high reliability of directional ground protection can be reached even with high-resistance earth-faults. The possibility of operating the network with accurately compensated phase-to-earth capacity currents contributes to higher safety of the network operation.

References European Patent EP 1817829

Illustrations

Voltage symmetrization system: Phase-to-earth capacity unbalance influences zero sequence voltage in the network: the higher the phase-to-earth capacity unbalance, the higher the value of zero sequence voltage during arc-suppression coil tuning, and thus the higher the difference in phase voltage.
Phase-to-earth capacity unbalance influences zero sequence voltage in the network: the higher the phase-to-earth capacity unbalance, the higher the value of zero sequence voltage during arc-suppression coil tuning, and thus the higher the difference in phase voltage.
Voltage symmetrization system: Arc-suppression coil tuning in an unbalanced network with blocked function of automatic voltage symmetrization VSS (see left) and with unblocked function (see right).
Arc-suppression coil tuning in an unbalanced network with blocked function of automatic voltage symmetrization VSS (see left) and with unblocked function (see right).

Worked examples

Example 1 — a first encounter with Voltage symmetrization system

Start with the simplest possible case. Write down what Voltage symmetrization system claims or describes in one sentence, then invent the smallest concrete situation in which that sentence is true. In engineering, the smallest case is usually a single object, a single equation or a single measurement. Check that every symbol or term in your sentence has a meaning in that case.

Example 2 — changing one variable

Take the situation from Example 1 and change exactly one quantity: double it, halve it, or set it to zero. Predict what should happen to Voltage symmetrization system before you calculate. Comparing your prediction with the result is the fastest way to find out whether you understand the idea or only the words.

Example 3 — an exam-style question

Typical questions about Voltage symmetrization system ask you to (a) state it precisely, (b) apply it to given data, and (c) explain a limitation. Practise writing all three answers in under five minutes; the third part is what separates a full-mark answer from an average one.

Applications of Voltage symmetrization system

In research
Voltage symmetrization system appears in engineering research whenever the underlying quantities have to be modelled precisely. Papers usually cite it as a starting assumption and then explore where it breaks down.
In technology and industry
Engineering practice reuses Voltage symmetrization system in design rules, simulations and safety margins. Knowing the idea lets you read a specification sheet and understand why the numbers look the way they do.
In the classroom
Voltage symmetrization system is common in secondary-school and first-year university syllabi. It links to neighbouring topics Power engineering, so understanding it makes those chapters shorter.
In everyday life
Look for Voltage symmetrization system outside the textbook — in sport, cooking, traffic, electronics or the sky above you. An example you found yourself is remembered far longer than one you were given.
Ask Teacher Smith questions about this articleOpens your AI tutor with a question about “Voltage symmetrization system” →

Affiliate

Preply — study more efficiently by working with a personal tutor. 50% off.

How to study Voltage symmetrization system in 20 minutes

  1. Read the reference excerpt below once, without taking notes.
  2. Close the page and write down what Voltage symmetrization system means in your own words.
  3. Compare your version with the excerpt and mark what you missed.
  4. Work through the three examples above with pen and paper.
  5. Explain Voltage symmetrization system out loud to somebody else — or to Teacher Smith in the lgStudy chat.

Frequently asked questions

What is Voltage symmetrization system in simple terms?

Voltage Symmetrization System (VSS) was developed especially for electric power networks with great phase voltage unbalance. It is a three-phase system which enables earth-fault current and charging current elimination.

Why does Voltage symmetrization system matter?

Because it connects several engineering ideas at once: it gives you a definition you can apply, a quantity you can calculate, and a way to check whether a result is plausible.

How should I study Voltage symmetrization system?

Read the excerpt, restate it from memory, then work through the examples and applications listed on this page. The five-step study plan above takes about twenty minutes.

What does this page cover?

It gives you a compact reference excerpt plus original lgStudy explanations, examples, applications and study material on Voltage symmetrization system.